Solid-state ion sensors with a liquid junction-free polymer membrane-based reference electrode for blood analysis

被引:48
作者
Yoon, HJ
Shin, JH
Lee, SD
Nam, H
Cha, GS
Strong, TD
Brown, RB
机构
[1] Kwangwoon Univ, Dept Chem, Chem Sensor Res Grp, Nowon Ku, Seoul 139701, South Korea
[2] Univ Michigan, Dept Elect Engn & Comp Sci, Ctr Integrated MicroSyst, Ann Arbor, MI 48109 USA
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2000年 / 64卷 / 1-3期
关键词
ion-selective electrode; all-solid-state ion sensors; liquid junction-free reference electrode; miniaturized ion sensors; polyurethane-based ion-selective membranes;
D O I
10.1016/S0925-4005(99)00476-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A set of ion-selective membranes for the measurement of clinically relevant electrolytes, i.e., K+, Na+, Ca2+, H+ and Cl-, and a solvent-processible polyurethane (PU)-based reference membrane were cast on metal electrodes patterned on small ceramic plates, and on silicon-based sensors. Since the liquid junction-free PU membrane-based reference electrode provides a constant potentiometric signal for an extended period of time, accurate determination of blood electrolytes could be made without using a separate reference flow. The PU membrane-based reference electrodes not only improve the mass producibility of miniaturized solid-state ion sensors but also simplify the configuration of flow cell. cartridges without compromising their analytical performance. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 15 条
[1]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[2]  
Bakker E, 1999, ELECTROANAL, V11, P788, DOI 10.1002/(SICI)1521-4109(199907)11:10/11<788::AID-ELAN788>3.3.CO
[3]  
2-W
[4]  
Burtis C.A., 1994, Tietz Textbook of Clinical Chemistry
[5]   RESPONSE OF ION-SELECTIVE FIELD-EFFECT TRANSISTORS TO CARBON-DIOXIDE AND ORGANIC-ACIDS [J].
FOGT, EJ ;
UNTEREKER, DF ;
NORENBERG, MS ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1985, 57 (09) :1995-1998
[6]  
LAUKS IR, 1988, Patent No. 4933048
[7]   Solvent-processible polymer membrane-based liquid junction-free reference electrode [J].
Lee, HJ ;
Hong, US ;
Lee, DK ;
Shin, JH ;
Nam, H ;
Cha, GS .
ANALYTICAL CHEMISTRY, 1998, 70 (16) :3377-3383
[8]  
Lee JS, 1999, ELECTROANAL, V11, P260, DOI 10.1002/(SICI)1521-4109(199904)11:4<260::AID-ELAN260>3.0.CO
[9]  
2-#
[10]   Effect of transmembrane electrolyte diffusion on the detection limit of carrier-based potentiometric ion sensors [J].
Mathison, S ;
Bakker, E .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :303-309