Three-region MRI-based whole-body attenuation correction for automated PET reconstruction

被引:35
作者
Steinberg, Jeffrey [1 ]
Jia, Guang [2 ]
Sammet, Steffen [2 ]
Zhang, Jun [2 ]
Hall, Nathan [2 ]
Knopp, Michael V. [2 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Ohio State Univ, Dept Radiol, Columbus, OH 43210 USA
关键词
PET/MRI development; Multimodal imaging; PET attenuation correction; PET reconstruction; Segmentation; DUAL-MODALITY PET/CT; PET/MRI; CT; BRAIN; BONE;
D O I
10.1016/j.nucmedbio.2009.11.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: In this study we proposed and developed a simple attenuation mapping approach based on magnetic resonance imaging (MRI) for the purpose of reconstructing positron emission tomography (PET) images in PET/MRI imaging devices. Methods: After experimental development, an in vivo calibration was performed by whole-body scanning of five beagles on both a PET/CT and an MRI. The attenuation was determined by using an automated segmentation algorithm to segment regions of background, lung, soft tissue and bone, and assigning them values of 0.002, 0.030, 0.098 and 0.130 cm(-1), respectively. Results: The CT-attenuated and MRI-attenuated PET images had average standardized uptake values (SUVs) that differed by 1-6% for most regions of interest (ROIs). Also, mean relative differences (MRDs) between the images were between 5% and 9% for most regions. The only exception is bone, where the three-region MRI-attenuated PET images had an SUV 10% less on average than the CT-attenuation images, and the MRD averaged 14%. Also, additional segmentation of the bone in the four-region MRI-attenuated PET images reduced the SUV difference to 3% and the MRD to 6%. Conclusion: Therefore, despite the improvements in the four-region segmentation, the three-region segmentation, without delineation of osseous tissues, produces high-quality images that are sufficient for most expected clinical and research purposes. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:227 / 235
页数:9
相关论文
共 34 条
[1]   Whole-body dual-modality PET/CT and whole-body MRI for tumor staging in oncology [J].
Antoch, G ;
Vogt, FM ;
Freudenberg, LS ;
Nazaradeh, F ;
Goehde, SC ;
Barkhausen, J ;
Dahmen, G ;
Bockisch, A ;
Debatin, JF ;
Ruehm, SG .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 290 (24) :3199-3206
[2]   Staging of regional nodes in AJCC stage I and II melanoma:: 18FDG PET imaging versus sentinel node detection [J].
Belhocine, T ;
Pierard, G ;
de Labrassinne, M ;
Lahaye, T ;
Rigo, P .
ONCOLOGIST, 2002, 7 (04) :271-278
[3]   Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology [J].
Beyer, T ;
Antoch, G ;
Blodgett, T ;
Freudenberg, LF ;
Akhurst, T ;
Mueller, S .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) :588-596
[5]  
CASEY ME, 1995, P 1995 INT M FULL 3, P61
[6]  
Catana C, 2006, J NUCL MED, V47, P1968
[7]   Exact and approximate rebinning algorithms for 3-D PET data [J].
Defrise, M ;
Kinahan, PE ;
Townsend, DW ;
Michel, C ;
Sibomana, M ;
Newport, DF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :145-158
[8]   Segmentation of skull and scalp in 3-D human MRI using mathematical morphology [J].
Dogdas, B ;
Shattuck, DW ;
Leahy, RM .
HUMAN BRAIN MAPPING, 2005, 26 (04) :273-285
[9]  
Gaa J, 2004, EUR J MED RES, V9, P309
[10]   MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration [J].
Hofmann, Matthias ;
Steinke, Florian ;
Scheel, Verena ;
Charpiat, Guillaume ;
Farquhar, Jason ;
Aschoff, Philip ;
Brady, Michael ;
Schoelkopf, Bernhard ;
Pichler, Bernd J. .
JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (11) :1875-1883