Determination of poorly fluorescent carbamate pesticides in water, bendiocarb and promecarb, using cyclodextrin nanocavities and related media

被引:47
作者
Pacioni, Natalia L. [1 ]
Veglia, Alicia V. [1 ]
机构
[1] Univ Nacl Cordoba, Fac Ciencias Quim, INFIQC, Dept Quim Organ, RA-5000 Cordoba, Argentina
关键词
bendiocarb; promecarb; cyclodextrin nanocavities; molecular nanosensor; carbamate pesticides; chitosan; propylamine effects;
D O I
10.1016/j.aca.2006.10.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The effect of native cyclodextrins (alpha, beta, or gamma CD with six, seven and eight glucose units, respectively), hydroxypropyl-beta-cyclodextrin (HPCD), chitosan (CHT) and glucose in water solution or water with n-propylamine (PA) as co-solvent upon the UV-vis and fluorescence properties of poorly fluorescent N-methyl carbamates pesticides (C) as bendiocarb (2,2-dimethyl-1,3-benzodioxol-4-ol methylcarbamate, BC) and promecarb (3-methyl-5-(1-methylethyl)phenol methylcarbame, PC) was examined. Fluorescent enhancement was found for both substrates with all CDs in water or PA-water except from PC with alpha CD. The addition of CHT increases the fluorescence of BC but decreases the fluorescence of PC, and glucose addition gives in both cases no spectral changes. Host-guest interaction was clearly determined by fluorescence enhancement with PCD and HPCD with a 1:1 stoichiometry for the complexes (C:CD). The values obtained for the association constants (K-A, M-1) were (6 +/- 2) x 10(2) and (2.3 +/- 0.3) x 10(2) for BC:beta CD and BC:HPCD complexes, respectively. For PC: PCD and PC: HPCD the values of KA were (19 2) x 102 and (21 2) x 102, respectively. The ratio of the fluorescence quantum yields for the bound and free substrates (phi(CCD)/phi(C)) was in the range 1.74-3.8. The limits of detection (L-D, mu g mL(-1)) for the best conditions were (0.57 +/- 0.02) for BC with HPCD and (0.091 +/- 0.002) for PC with PCD in water. Application to the analysis in pesticide spiked samples of tap water and fruit yields satisfactory apparent recoveries (84-114%), and for the extraction procedure in fruits and a commercial formulation, recoveries were of 81-98% and 104%, respectively. The method is rapid, simple, direct, sensitive and useful for pesticide analysis. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 47 条
[21]   Cyclodextrin enhanced fluorimetric method for the determination of tryptamine [J].
Galian, RE ;
Veglia, AV ;
de Rossi, RH .
ANALYST, 1998, 123 (07) :1587-1591
[22]   Development of a single fluorescence-based optosensor for rapid simultaneous determination of fungicides benomyl and thiabendazole in waters and commercial formulations [J].
García-Reyes, JF ;
Ortega-Barrales, P ;
Molina-Díaz, A .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (08) :2197-2202
[23]   Simple and rapid determination of N-methylcarbamate pesticides in citrus fruits by electrospray ionization tandem mass spectrometry [J].
Goto, T ;
Ito, Y ;
Oka, H ;
Saito, I ;
Matsumoto, H ;
Nakazawa, H .
ANALYTICA CHIMICA ACTA, 2003, 487 (02) :201-209
[24]   CORRELATION OF THE BASE STRENGTHS OF AMINES [J].
HALL, HK .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1957, 79 (20) :5441-5444
[25]   Regulatory limits for pesticide residues in water - (IUPAC Technical Report) [J].
Hamilton, DJ ;
Ambrus, A ;
Dieterle, RM ;
Felsot, AS ;
Harris, CA ;
Holland, PT ;
Katayama, A ;
Kurihara, N ;
Linders, J ;
Unsworth, J ;
Wong, SS .
PURE AND APPLIED CHEMISTRY, 2003, 75 (08) :1123-1155
[26]   Industrial applications of cyclodextrins [J].
Hedges, AR .
CHEMICAL REVIEWS, 1998, 98 (05) :2035-2044
[27]  
HELRICH K, 1990, OFFICIAL METHODS ANA, P214
[28]   Chemiluminescence determination of carbofuran at trace levels in lettuce and waters by flow-injection analysis [J].
Huertas-Pérez, JF ;
Gámiz-Gracia, L ;
García-Campaña, AM ;
González-Casado, A ;
Vidal, JLM .
TALANTA, 2005, 65 (04) :980-985
[29]  
Inczedy J., 1998, COMPENDIUM ANAL NOME
[30]  
KALYANASUNDARAM K, 1978, PHOTOCHEMISTRY MICRO, pCH1