Challenges of implementing Point-of-Care Testing (POCT) glucose meters in a pediatric acute care setting

被引:20
作者
Kavsak, PA
Zielinski, N
Li, DL
McNamara, PJ
Adeli, K
机构
[1] Univ Toronto, Hosp Sick Children, Div Clin Biochem, Toronto, ON M5G 1X8, Canada
[2] Univ Toronto, Hosp Sick Children, Div Neonatol, Toronto, ON M5G 1X8, Canada
关键词
glucose measurements; NICU; glucose meters; Point-of-Care Testing; POCT;
D O I
10.1016/j.clinbiochem.2004.06.003
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To investigate factors contributing to analytical bias in POCT glucose values generated by the NICU versus the core laboratory. Methods: The LifeScan Flexx hospital system glucose meters (SureStep) were used in precision and comparison studies between the NICU and laboratory (ABL715 and Vitros 950). Results: Analysis of 40 neonatal blood samples revealed a positive bias between the NICU glucose meters versus either the laboratory glucose meter or instrument (mean difference of 0.28 and 0.21 mmol/L, respectively). Linear regression analysis (R-2 = 0.0584) of the difference in glucose results versus time elapsed between measurements indicated that the bias observed between the NICU and laboratory glucose meters was not due to in vitro glycolysis for samples transported on ice. Further analysis indicated that the bias appeared to be mostly operator driven, with different NICU operators exhibiting different mean biases. Increasing the amount of blood applied to the SureStep Pro test strip (e.g., 60 vs. 20 muL), led to higher values for glucose concentration for the same blood. Nearly 50% of all glucose values reported for the NICU were obtained by the SureStep Flexx glucose meters in a 3-month period following the introduction of POCT, yet the number of laboratory-reported glucose results for the same period increased by 21% as compared to the previous year. Conclusions: Operator error appears to be a source of bias present between the NICU and laboratory, and despite glucose meter utilization in the NICU, the number of glucose measurements by the central laboratory increased after POCT introduction. (C) 2004 The Canadian Society of Clinical Chemists. All rights reserved.
引用
收藏
页码:811 / 817
页数:7
相关论文
共 12 条
[1]  
Alex C P, 1998, J Perinatol, V18, P45
[2]   Controversies regarding definition of neonatal hypoglycemia: Suggested operational thresholds [J].
Cornblath, M ;
Hawdon, JM ;
Williams, AF ;
Aynsley-Green, A ;
Ward-Platt, MP ;
Schwartz, R ;
Kalhan, SC .
PEDIATRICS, 2000, 105 (05) :1141-1145
[3]  
KEFFER JH, 1995, AM J CLIN PATHOL, V104, pS107
[4]  
Kilgore ML, 1998, CLIN CHEM, V44, P1597
[5]  
LUM G, 1996, AM J CLIN PATHOL, V106, P300
[6]  
McNamara PJ, 2001, ACTA PAEDIATR, V90, P1033
[7]  
SALEM M, 1991, JAMA-J AM MED ASSOC, V266, P382
[8]   Status of point-of-care testing: Promise, realities, and possibilities [J].
St-Louis, P .
CLINICAL BIOCHEMISTRY, 2000, 33 (06) :427-440
[9]   An evaluation of three glucose meter systems and their performance in relation to criteria of acceptability for neonatal specimens [J].
St-Louis, P ;
Ethier, J .
CLINICA CHIMICA ACTA, 2002, 322 (1-2) :139-148
[10]  
Tang ZP, 2000, ARCH PATHOL LAB MED, V124, P1135