Correlation between simple clinical parameters and the in vitro humidification characteristics of filter heat and moisture exchangers

被引:22
作者
Beydon, L
Tong, D
Jackson, N
Dreyfuss, D
Brochard, L
Kalfon, P
Guerot, E
Similowski, T
Djedaini, K
Rabbat, A
Louville, P
Moine, P
机构
[1] HOP HENRI MONDOR,F-94010 CRETEIL,FRANCE
[2] AP HP,PHARM CENT HOP,PARIS,FRANCE
[3] HOP LOUIS MOURIER,F-92701 COLOMBES,FRANCE
[4] HOP LA PITIE SALPETRIERE,PARIS,FRANCE
[5] HOP BOUCICAULT,PARIS,FRANCE
[6] HOP LOUIS MOURIER,F-92701 COLOMBES,FRANCE
[7] HOP HOTEL DIEU,PARIS,FRANCE
[8] HOP NECKER ENFANTS MALAD,PARIS,FRANCE
[9] HOP BICETRE,LE KREMLIN BICETR,FRANCE
关键词
D O I
10.1378/chest.112.3.739
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: This study on ventilated patients in ICUs examined a large sample of heat and moisture exchanger filters (HMEFs) to determine whether simple clinical parameters are correlated with exchanger humidity output. Design: A total of 594 HMEFs (18 types of HMEF) were tested in nine university hospital ICUs, Patients: Each HMEF was tested on one different unselected and consecutive patient for 24 h. Interventions: The following parameters were rated at each tracheal aspiration on a scale of 0 to 3: secretion abundance, viscosity (Visc), suction catheter adherence (Adh) to the endotracheal tube, and the amount of water condensed in the flex tube (Cond), Individual values for each type of HMEF and each variable were averaged and correlated with the humidity output (HO) of the HMEFs, values which were supplied by the manufacturers, Results: There were significant correlations between HO and Cond (r=0.82, p<10(-3)), Vise (r=-0.67, p=0.002), and Adh (r=-0.56, p=0.01). A second study recorded the same variables, for three consecutive 24-h periods, using first a high-humidifying HMEF (DAR Hygrobac), followed by a lo cv-humidifying one (Pall BB22-15), and again DAR Hygrobac. Vise and Adh were higher (p<0.05) and Cond was lower (p<0.05) with the Pall than with the DAR. Conclusions: Simple clinical parameters correlate well with the efficiency of HMEFs. The apparent water condensed in the flex tubing seems to be the best indicator of the humidifying efficiency of HMEFs.
引用
收藏
页码:739 / 744
页数:6
相关论文
共 22 条
[1]   HUMIDIFICATION IN THE INTENSIVE-CARE UNIT - PROSPECTIVE-STUDY OF A NEW PROTOCOL UTILIZING HEATED HUMIDIFICATION AND A HYGROSCOPIC CONDENSER HUMIDIFIER [J].
BRANSON, RD ;
DAVIS, K ;
CAMPBELL, RS ;
JOHNSON, DJ ;
POREMBKA, DT .
CHEST, 1993, 104 (06) :1800-1805
[2]   EFFECTS OF DRY ANESTHETIC GASES ON TRACHEOBRONCHIAL CILIATED EPITHELIUM [J].
CHALON, J ;
MALEBRANCHE, J ;
LOEW, DAY .
ANESTHESIOLOGY, 1972, 37 (03) :338-+
[3]  
CIGADA M, 1989, INTENSIVE CARE WORLD, V7, P98
[4]   ENDOTRACHEAL-TUBE OCCLUSION ASSOCIATED WITH THE USE OF HEAT AND MOISTURE EXCHANGERS IN THE INTENSIVE-CARE UNIT [J].
COHEN, IL ;
WEINBERG, PF ;
FEIN, IA ;
ROWINSKI, GS .
CRITICAL CARE MEDICINE, 1988, 16 (03) :277-279
[5]   PERFORMANCE OF A HYDROPHOBIC HEAT AND MOISTURE EXCHANGER AT DIFFERENT AMBIENT-TEMPERATURES [J].
CROCI, M ;
ELENA, A ;
SOLCA, M .
INTENSIVE CARE MEDICINE, 1993, 19 (06) :351-352
[6]   EVOLUTION OF HEAT AND MOISTURE IN RESPIRATORY TRACT DURING ANESTHESIA WITH A NON-REBREATHING SYSTEM [J].
DERY, R .
CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1973, 20 (03) :296-309
[7]   CHANGING HEAT AND MOISTURE EXCHANGERS EVERY 48 HOURS RATHER THAN 24 HOURS DOES NOT AFFECT THEIR EFFICACY AND THE INCIDENCE OF NOSOCOMIAL PNEUMONIA [J].
DJEDAINI, K ;
BILLIARD, M ;
MIER, L ;
LEBOURDELLES, G ;
BRUN, P ;
MARKOWICZ, P ;
ESTAGNASIE, P ;
COSTE, F ;
BOUSSOUGANT, Y ;
DREYFUSS, D .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (05) :1562-1569
[8]  
DREYFUSS D, 1995, AM J RESP CRIT CARE, V151, P986
[9]   PROSPECTIVE-STUDY OF NOSOCOMIAL PNEUMONIA AND OF PATIENT AND CIRCUIT COLONIZATION DURING MECHANICAL VENTILATION WITH CIRCUIT CHANGES EVERY 48 HOURS VERSUS NO CHANGE [J].
DREYFUSS, D ;
DJEDAINI, K ;
WEBER, P ;
BRUN, P ;
LANORE, JJ ;
RAHMANI, J ;
BOUSSOUGANT, Y ;
COSTE, F .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 143 (04) :738-743
[10]   TEMPERATURE, HUMIDITY AND MUCUS FLOW IN INTUBATED TRACHEA [J].
FORBES, AR .
BRITISH JOURNAL OF ANAESTHESIA, 1974, 46 (01) :29-34