A highly selective and sensitive disposable carbon composite PVC-based membrane for determination of lead ion in environmental samples

被引:45
作者
Abbaspour, A. [1 ]
Mirahmadi, E. [1 ]
Khalafi-nejad, A. [1 ]
Babamohammadi, S. [1 ]
机构
[1] Shiraz Univ, Dept Chem, Coll Sci, Shiraz 7145685464, Iran
关键词
Coated wire electrode; Carbon composite; Lead; PVC; Butyl-3-(2-phenylhydrazono)indolin-2-one; COATED-WIRE ELECTRODE; NEUTRAL CARRIER; GLASSY-CARBON; DISULFIDE; SENSOR; DETECTORS; OXIDATION; LIMITS; ACID;
D O I
10.1016/j.jhazmat.2009.09.101
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A Pt wire coated with phenyl hydrazone derivative-carbon composite in a poly(vinyl chloride) membrane was used for detection of lead. The sensor had a Nernstian slope of 29.46 +/- 0.41 mV/decade over a wide linear concentration range of 7.7 x 10(-7) to 1.0 x 10(-1) mol L-1 for Pb(NO3)(2). The detection limit was 3.2 x 10(-7) mol L-1 and the electrode was applicable in the pH range of 3.7-6.3. It had a short response time of approximately 6 s and was used at least for 70 days. The electrode has exhibited good selectivity for Pb(II) relative to 19 other metal ions. The functionality of the proposed sensor was also investigated in binary water-alcohol mixture and it concluded that 23% water-methanol and 20% water-ethanol content could not bring out any changes in its potential. The practical analytical utility-of the electrode was demonstrated by measurement of Pb(II) in mineral rock and potentiometric titration of sulfate anion. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:656 / 661
页数:6
相关论文
共 45 条
[1]   Carbon composition PVC based membrane in a highly selective and sensitive coated wire electrode for silver ion [J].
Abbaspour, A ;
Izadyar, A ;
Sharghi, H .
ANALYTICA CHIMICA ACTA, 2004, 525 (01) :91-96
[2]   Lead(II)-selective electrode based on phenyl disulfide [J].
Abbaspour, A ;
Khajeh, B .
ANALYTICAL SCIENCES, 2002, 18 (09) :987-991
[3]   Copper(II)-selective electrode based on dithioacetal [J].
Abbaspour, A ;
Kamyabi, MA .
ANALYTICA CHIMICA ACTA, 2002, 455 (02) :225-231
[4]   Thiocyanate-selective electrode based on unsymmetrical benzoN4 nickel(II) macrocyclic complexes [J].
Abbaspour, A ;
Kamyabi, MA ;
Esmaeilbeig, AR ;
Kia, R .
TALANTA, 2002, 57 (05) :859-867
[5]   Chromium(III) ion-selective electrode based on 4-dimethylaminoazobenzene [J].
Abbaspour, A ;
Izadyar, A .
TALANTA, 2001, 53 (05) :1009-1013
[6]   Highly selective electrode for Nickel(II) ion based on 1.5-diphenylthiocarbazone (dithizone) [J].
Abbaspour, A ;
Izadyar, A .
MICROCHEMICAL JOURNAL, 2001, 69 (01) :7-11
[7]   Lead-selective electrode by using benzyl disulphide as ionophore [J].
Abbaspour, A ;
Tavakol, F .
ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) :145-149
[8]   Platinum electrode coated with a bentonite-carbon composite as an environmental sensor for detection of lead [J].
Abbaspour, Abdolkarim ;
Izadyar, Anahita .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (05) :1559-1565
[9]   Capability of a carbon-polyvinylchloride composite electrode for the detection of dopamine, ascorbic acid and uric acid [J].
Aguilar, R ;
Dávila, MM ;
Elizalde, MP ;
Mattusch, J ;
Wennrich, R .
ELECTROCHIMICA ACTA, 2004, 49 (06) :851-859
[10]   A PVC-graphite composite electrode for electroanalytical use. Preparation and some applications [J].
Albertus, F ;
Llerena, A ;
Alpizar, J ;
Cerda, V ;
Luque, M ;
Rios, A ;
Valcarcel, M .
ANALYTICA CHIMICA ACTA, 1997, 355 (01) :23-32