Monte Carlo simulation of x-ray spectra in mammography

被引:40
作者
Ng, KP [1 ]
Kwok, CS [1 ]
Tang, FH [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Optometry & Radiog, Kowloon, Hong Kong, Peoples R China
关键词
D O I
10.1088/0031-9155/45/5/315
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A model for generating x-ray spectra in mammography is presented. This model used the ITS Version 3 Monte Carlo code for simulating the radiation transport. Various target/filter combinations such as tungsten/aluminium, molybdenum/molybdenum, molybdenum/rhodium and rhodium/rhodium were used in the simulation. Both bremsstrahlung and characteristic x-ray production were included in the model. The simulated x-ray emission spectra were compared with two sets of spectra, those of Boone et al (1997 Med. Phys. 24 1863-74) and IPEM report 78. The chi(2) test was used for the overall goodness of fit of the spectral data. There is good agreement between the simulated x-ray spectra and the comparison spectra as the test yielded a probability Value of nearly 1. When the transmitted x-ray spectra for specific target/filter combinations were generated and compared with a measured molybdenum/rhodium spectrum and spectra generated in IPEM report 78, close agreement is also observed. This was demonstrated by the probability value for the chi(2) test being almost 1 for all the cases. However, minor differences between the simulated spectra and the 'standard' ones are observed.
引用
收藏
页码:1309 / 1318
页数:10
相关论文
共 18 条
[1]  
[Anonymous], 1986, NUCL SCI ENG, DOI DOI 10.13182/NSE86-A18182
[2]  
Bevington R., 1969, DATA REDUCTION ERROR
[3]   Off-axis x-ray spectra: A comparison of Monte Carlo simulated and computed x-ray spectra with measured spectra [J].
Bhat, M ;
Pattison, J ;
Bibbo, G ;
Caon, M .
MEDICAL PHYSICS, 1999, 26 (02) :303-309
[4]   Diagnostic x-ray spectra: A comparison of spectra generated by different computational methods with a measured spectrum [J].
Bhat, M ;
Pattison, J ;
Bibbo, G ;
Caon, M .
MEDICAL PHYSICS, 1998, 25 (01) :114-120
[5]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[6]  
BIRCH R, 1979, SRS30 HOSP PHYS ASS
[7]   Calculated mammographic spectra confirmed with attenuation curves for molybdenum, rhodium, and tungsten targets [J].
Blough, MM ;
Waggener, RG ;
Payne, WH ;
Terry, JA .
MEDICAL PHYSICS, 1998, 25 (09) :1605-1612
[8]   THE 3 PARAMETER EQUIVALENT SPECTRA AS AN INDEX OF BEAM QUALITY [J].
BOONE, JM .
MEDICAL PHYSICS, 1988, 15 (03) :304-310
[9]   Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography [J].
Boone, JM ;
Fewell, TR ;
Jennings, RJ .
MEDICAL PHYSICS, 1997, 24 (12) :1863-1874
[10]  
CRANLEY K, 78 IPEM REP