Background and aims: We compared contrast-enhanced power Doppler sonography (CEPD) and phase-inversion harmonic imaging (PIHI) in the assessment of liver lesion vascularity and characterization of focal liver lesions. Materials and methods: We examined 101 focal liver lesions by CEPD and PIHI using Optison as echo-enhancing agent. Amount and architecture of lesion vascularity and the kinetics of contrast enhancement in the lesions were analyzed. A tumor diagnosis was assessed after each examination. Results: Analysis of tumor vascularity was not possible in 30 liver lesions (30%) due to motion or blooming artifacts by CEPD. Vascularity was detected in 61% of liver lesions by CEPD and in 95% by PIHI. PIHI identified significantly more tumor vascularity pattern (93%) than CEPD (57%). Specific lesion diagnosis based on PIHI led to correct results in 92% compared to 59% by CEPD. Conclusion: PIHI is highly efficient in detecting tumor vascularity and is superior to CEPD in characterizing focal liver lesions.
引用
收藏
页码:63 / 72
页数:10
相关论文
共 45 条
[11]  
Burns PN, 1996, CLIN RADIOL, V51, P50
[12]   Pulse inversion imaging of liver blood flow - Improved method for characterizing focal masses with microbubble contrast [J].
Burns, PN ;
Wilson, SR ;
Simpson, DH .
INVESTIGATIVE RADIOLOGY, 2000, 35 (01) :58-71
[13]  
BURNS PN, 1994, ULTRASON, P1547, DOI 10.1109/ULTSYM.1994.401886
[14]   Power versus conventional color Doppler sonography: Comparison in the depiction of vasculature in liver tumors [J].
Choi, BI ;
Kim, TK ;
Han, JK ;
Chung, JW ;
Park, JH ;
Han, MC .
RADIOLOGY, 1996, 200 (01) :55-58
[15]  
Cosgrove D, 1996, CLIN RADIOL, V51, P44
[16]   On the feasibility of real time, in vivo harmonic imaging with proteinaceous microspheres [J].
Forsberg, F ;
Goldberg, BB ;
Liu, JB ;
Merton, DA ;
Rawool, NM .
JOURNAL OF ULTRASOUND IN MEDICINE, 1996, 15 (12) :853-860
[17]  
FORSBERG F, 1994, J ULTRAS MED, V13, P357
[18]   COLOR DOPPLER SONOGRAPHY OF HEPATIC-TUMORS WITH A GALACTOSE-BASED CONTRAST AGENT - CORRELATION WITH ANGIOGRAPHIC FINDINGS [J].
FUJIMOTO, M ;
MORIYASU, F ;
NISHIKAWA, K ;
NADA, T ;
OKUMA, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) :1099-1104
[19]   HEPATIC-TUMORS - SIGNAL ENHANCEMENT AT DOPPLER US AFTER INTRAVENOUS-INJECTION OF A CONTRAST AGENT [J].
GOLDBERG, BB ;
HILPERT, PL ;
BURNS, PN ;
LIU, JB ;
NEWMAN, LM ;
MERTON, DA ;
WITLIN, LA .
RADIOLOGY, 1990, 177 (03) :713-717
[20]  
HAERTEN R, 1999, ELEKTROMEDICA, V67, P56