A two channel gas diffusion flow injection (GDFI) system was utilized successfully for the quantitative determination of cyanide. The analytical procedure is based on the complexation reaction in the acceptor stream between nickel ions in ammoniacal solution and the cyanide ions formed as a result of the diffusion of hydrogen cyanide from the acidified donor stream where the sample is injected. The design and the chemical parameters of the GDFI system were optimized with respect to sensitivity and sampling rate. The interference effect of a number of frequently encountered chemical species on the analytical determination was investigated in real samples and methods for their removal were developed When applied to real samples where the cyanide ions are predominantly complexed with various metal ions the GDFI method was found to give results close to those obtained by standard distillation methods for weak acid dissociable (WAD) cyanide. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:103 / 109
页数:7
相关论文
共 23 条
[1]  
*APHA, 1992, STAND METH EX WAT WA
[2]   DETERMINATION OF TOTAL CYANIDE IN THIOCYANATE-CONTAINING WASTEWATERS [J].
CSIKAI, NJ ;
BARNARD, AJ .
ANALYTICAL CHEMISTRY, 1983, 55 (11) :1677-1682
[3]  
FANG ZL, 1988, ANAL CHIM ACTA, V214, P41
[4]   SEQUENTIAL FLOW-INJECTION DETERMINATION OF CYANIDE AND WEAK METAL CYANIDE COMPLEXES WITH FLOW-THROUGH HETEROGENEOUS MEMBRANE ELECTRODES [J].
FIGUEROLA, E ;
FLORIDO, A ;
AGUILAR, M ;
DEPABLO, J ;
ALEGRET, S .
ANALYTICA CHIMICA ACTA, 1988, 215 (1-2) :283-288
[5]  
FISCHER RB, 1968, BASIC THEORY PRACTIC, P525
[6]   ENHANCEMENT OF SENSOR SELECTIVITY BY GAS-DIFFUSION SEPARATION .1. FLOW-INJECTION POTENTIOMETRIC DETERMINATION OF CYANIDE WITH A METALLIC SILVER-WIRE ELECTRODE [J].
FRENZEL, W ;
LIU, CY ;
OLEKSYFRENZEL, J .
ANALYTICA CHIMICA ACTA, 1990, 233 (01) :77-84
[7]   GAS-DIFFUSION SEPARATION AND FLOW-INJECTION POTENTIOMETRY - A FRUITFUL ALLIANCE OF ANALYTICAL METHODS [J].
FRENZEL, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 336 (01) :21-28
[8]  
HAJHUSSEIN AT, 1988, ANAL LETT, V21, P1285
[9]   MATHEMATICAL-MODELING OF A FLOW-INJECTION SYSTEM WITH A MEMBRANE SEPARATION MODULE [J].
KOLEV, SD ;
VANDERLINDEN, WE .
ANALYTICA CHIMICA ACTA, 1992, 268 (01) :7-27
[10]   COMPARISON OF PHOTOMETRY AND CONDUCTOMETRY FOR THE DETERMINATION OF TOTAL CARBONATE BY GAS PERMEATION FLOW-INJECTION ANALYSIS [J].
KUBAN, V ;
DASGUPTA, PK .
TALANTA, 1993, 40 (06) :831-840