Design of the monolithic polymers used in capillary electrochromatography columns

被引:237
作者
Svec, F [1 ]
Peters, EC [1 ]
Sykora, D [1 ]
Fréchet, JMJ [1 ]
机构
[1] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
关键词
reviews; monolithic columns; electrochromatography; polymers; monolithic;
D O I
10.1016/S0021-9673(99)01232-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Monolithic columns for capillary electrochromatography (CEC) are receiving quite remarkable attention. Both the simplicity of the in situ preparation and the large number of readily available chemistries make the monolithic separation media a vital alternative to capillary columns packed with particulate materials. This review summarizes the current state-of-the-art in this rapidly growing area of CEC with a focus on monolithic capillary columns prepared from synthetic polymers. Recent achievements in column technologies for both high-performance liquid chromatography and capillary electrophoresis are used as the starting point to highlight the influence of these well established analytical methods on the development of monolithic capillary columns for CEC. The effects of individual variables on the separation properties of monolithic capillaries are discussed in detail. The analytical potential of these columns is demonstrated with separations involving various families of compounds in different chromatographic modes. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:3 / 29
页数:27
相关论文
共 97 条
[41]   Capillary electrochromatographic separation of amino acid enantiomers with molecularly imprinted polymers as chiral recognition agents [J].
Lin, JM ;
Nakagama, T ;
Wu, XZ ;
Uchiyama, K ;
Hobo, T .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (01) :130-132
[42]   Molecularly imprinted polymer as chiral selector for enantioseparation of amino acids by capillary gel electrophoresis [J].
Lin, JM ;
Nakagama, T ;
Uchiyama, K ;
Hobo, T .
CHROMATOGRAPHIA, 1996, 43 (11-12) :585-591
[43]   Enantioseparation of D,L-phenylalanine by molecularly imprinted polymer particles filled capillary electrochromatography [J].
Lin, JM ;
Nakagama, T ;
Uchiyama, K ;
Hobo, T .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (10) :1489-1506
[44]   HIGH RESOLUTION LOW PRESSURE LIQUID-CHROMATOGRAPHY [J].
LYNN, TR ;
RUSHNECK, DR ;
COOPER, AR .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1974, 12 (02) :76-79
[45]   Ultrahigh pressure reversed-phase capillary liquid chromatography:: Isocratic and gradient elution using columns packed with 1.0-μm particles [J].
MacNair, JE ;
Patel, KD ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :700-708
[46]   Separation of neutral compounds by capillary electrokinetic chromatography using polyethyleneimine as replaceable cationic pseudostationary phase [J].
Maichel, B ;
Potocek, B ;
Gas, B ;
Chiari, M ;
Kenndler, E .
ELECTROPHORESIS, 1998, 19 (12) :2124-2128
[47]  
Majors RE, 1999, LC GC-MAG SEP SCI, V17, P212
[48]   Octadecylsilylated porous silica rods as separation media for reversed-phase liquid chromatography [J].
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Ishizuka, N ;
Tanaka, N .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3498-3501
[49]   Effect of domain size on the performance of octadecylsilylated continuous porous silica columns in reversed-phase liquid chromatography [J].
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Ishizuka, N ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 1998, 797 (1-2) :121-131
[50]   Effect of skeleton size on the performance of octadecylsilylated continuous porous silica columns in reversed-phase liquid chromatography [J].
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Ishizuka, N ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 1997, 762 (1-2) :135-146