Electrochemical and spectroscopic investigation of the reduction of dimethylglyoxime at mercury electrodes in the presence of cobalt and nickel

被引:49
作者
Baxter, LAM
Bobrowski, A
Bond, AM
Heath, GA
Paul, RL
Mrzljak, R
Zarebski, D
机构
[1] Stanislaw Staszic Univ Min & Met, Dept Mat Sci & Ceram, PL-30059 Krakow, Poland
[2] Australian Natl Univ, Res Sch Chem, Canberra, ACT 2601, Australia
[3] La Trobe Univ, Sch Chem, Bundoora, Vic 3083, Australia
[4] Monash Univ, Dept Chem, Melbourne, Vic 3168, Australia
关键词
D O I
10.1021/ac9703616
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Voltammograms (polarograms) obtained from solutions of cobalt and nickel containing dimethylglyoxime (dmgH(2)) are widely used for the trace determination of these metals, Detailed electrochemical and spectroscopic studies on the reduction process observed in the analytically important ammonia buffer media at mercury dropping, hanging, and pool electrodes are all consistent with an overall 10-electron reduction process, in which both the dmgH(2) ligand and cobalt ions are reduced in the adsorbed state: Co(II) + 2dmgH(2) reversible arrow (solution) [Co-II(dmgH)(2)] + 2H(+); [Co-II(dmgH)(2)] + Hg reversible arrow (electrode) [Co-II(dmgH)(2)](ads)-Hg; and [Co-II(dmgH)(2)](ads)Hg + 10e(-) + 10H(+) --> Co(Hg) + 2[2,3-bis(hydroxylamino)butane]. The limited solubility of the nickel complex in aqueous media restricts the range of studies that can be undertaken with this system, but an analogous mechanism is believed to occur, Low-temperature voltammetric studies in dichloromethane at a frozen hanging mercury drop electrode and in situ electron spin resonance electrochemical measurements on more soluble analogues of the dimethylglyoxime complexes are consistent with an initial one-electron reduction step being available in the absence of water, Deliberate addition of water to acetone solutions enables the influence of the aqueous environment on voltammograms and polarograms to be examined, The results of the present study are compared with the wide range of mechanisms proposed in other studies.
引用
收藏
页码:1312 / 1323
页数:12
相关论文
共 50 条
[1]   MULTIELEMENT DETERMINATION IN BIOLOGICAL-MATERIALS BY DIFFERENTIAL PULSE VOLTAMMETRY [J].
ADELOJU, SB ;
BOND, AM ;
BRIGGS, MH .
ANALYTICAL CHEMISTRY, 1985, 57 (07) :1386-1390
[2]   SYNTHESIS AND CHARACTERIZATION OF A DIPLATINUM(III)-TETRAKIS(ALPHA-DIOXIMATO) COMPLEX CONTAINING AN UNSUPPORTED METAL METAL BOND [J].
BAXTER, LAM ;
HEATH, GA ;
RAPTIS, RG ;
WILLIS, AC .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (17) :6944-6946
[5]  
BOBROWSKI A, 1988, REPORT U MINING META
[6]  
BOBROWSKI A, 1995, THESIS U MINING META
[7]  
BOSSA V, 1967, RIC SCI, V37, P402
[8]   ADSORPTIVE STRIPPING VOLTAMMETRY OF COBALT AND NICKEL IN FLOW SYSTEMS AT WALL-JET ELECTRODES [J].
BRETT, CMA ;
BRETT, AMCFO ;
PEREIRA, JLC .
ELECTROANALYSIS, 1991, 3 (07) :683-689
[9]  
BUDNIKOV GK, 1973, J ANAL CHEM-USSR+, V28, P301
[10]  
BURGER K, 1966, ACTA CHIM HUNG, V49, P113