Quantifying instrument errors in macromolecular X-ray data sets

被引:68
作者
Diederichs, Kay [1 ]
机构
[1] Univ Konstanz, Fac Biol, D-78457 Constance, Germany
来源
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY | 2010年 / 66卷
关键词
INTEGRATION;
D O I
10.1107/S0907444910014836
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An indicator which is calculated after the data reduction of a test data set may be used to estimate the (systematic) instrument error at a macromolecular X-ray source. The numerical value of the indicator is the highest signal-to-noise [I/sigma(I)] value that the experimental setup can produce and its reciprocal is related to the lower limit of the merging R factor. In the context of this study, the stability of the experimental setup is influenced and characterized by the properties of the X-ray beam, shutter, goniometer, cryostream and detector, and also by the exposure time and spindle speed. Typical values of the indicator are given for data sets from the JCSG archive. Some sources of error are explored with the help of test calculations using SIM_MX [Diederichs (2009), Acta Cryst. D65, 535-542]. One conclusion is that the accuracy of data at low resolution is usually limited by the experimental setup rather than by the crystal. It is also shown that the influence of vibrations and fluctuations may be mitigated by a reduction in spindle speed accompanied by stronger attenuation.
引用
收藏
页码:733 / 740
页数:8
相关论文
共 22 条
[11]   Integration, scaling, space-group assignment and post-refinement [J].
Kabsch, Wolfgang .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 2010, 66 :133-144
[12]   XDS [J].
Kabsch, Wolfgang .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 2010, 66 :125-132
[13]   The integration of macromolecular diffraction data [J].
Leslie, AGW .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2006, 62 :48-57
[14]   Integration of macromolecular diffraction data [J].
Leslie, AGW .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 1999, 55 :1696-1702
[15]  
LESLIE AGW, 1992, JNT CCP4 ESF EACBM N, V26
[16]   Improving radiation-damage substructures for RIP [J].
Nanao, MH ;
Sheldrick, GM ;
Ravelli, RBG .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2005, 61 :1227-1237
[17]   Processing of X-ray diffraction data collected in oscillation mode [J].
Otwinowski, Z ;
Minor, W .
MACROMOLECULAR CRYSTALLOGRAPHY, PT A, 1997, 276 :307-326
[18]   The finer things in X-ray diffraction data collection [J].
Pflugrath, JW .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 1999, 55 :1718-1725
[19]   Choice of data-collection parameters based on statistic modelling [J].
Popov, AN ;
Bourenkov, GP .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2003, 59 :1145-1153
[20]   Substructure solution with SHELXD [J].
Schneider, TR ;
Sheldrick, GM .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2002, 58 :1772-1779