The effect of biphasic inhalation profiles on the deposition and clearance of coarse (6.5 μm) bolus aerosols

被引:21
作者
Clark, Andrew R. [1 ]
Chambers, Carole B.
Muir, David
Newhouse, Michael T.
Paboojian, Steven
Schuler, Carlos
机构
[1] Nektar Therapeut, San Carlos, CA 94070 USA
[2] McMaster Univ, St Josephs Hosp, Barnett Med Aerosol Res Lab, Hamilton, ON, Canada
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 2007年 / 20卷 / 01期
关键词
deposition; bolus delivery; large particle deposition; low flow;
D O I
10.1089/jam.2006.0557
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The influence of particle size upon deposition in the human airways is well understood. Pharmaceutical aerosol formulators strive to generate fine aerosols with the potential to penetrate into the deep lung. However, flow rate can also have a major influence on deposition, particularly with coarse aerosols. This study investigated the use of biphasic flow profiles with low flow in the proximal conducting airway as a means of effecting efficient delivery of a coarse aerosol. The study shows that 6.5-mu m MMAD aerosol droplets can be deposited in the lung with high efficiency. The delivery technique achieved greater than 70% of the inhaled dose deposited in the whole lung and greater than 50% deposited in the lung periphery. Furthermore, the biphasic flow profiles used, with initial low flow segments of between 300 mL and 900 mL inhaled volume at 8 L/min, are practical flow regimens that should be acceptable to patients and that can be applied to single-breath dry powder inhalers. Twenty-four-hour clearance and Penetration Index measurements were used as a marker for peripheral deposition, and the data show a clear correlation between Penetration Index and 24-h retention.
引用
收藏
页码:75 / 82
页数:8
相关论文
共 14 条
[1]  
AGNEW JE, 1981, EUR J RESPIR DIS, V62, P239
[2]   HUMAN DEPOSITION AND CLEARANCE OF 6-MU-M PARTICLES INHALED WITH AN EXTREMELY LOW-FLOW RATE [J].
ANDERSON, M ;
PHILIPSON, K ;
SVARTENGREN, M ;
CAMNER, P .
EXPERIMENTAL LUNG RESEARCH, 1995, 21 (01) :187-195
[3]   THE USE OF LASER DIFFRACTION FOR THE EVALUATION OF THE AEROSOL CLOUDS GENERATED BY MEDICAL NEBULIZERS [J].
CLARK, AR .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1995, 115 (01) :69-78
[4]   MODELING THE DEPOSITION OF INHALED POWDERED DRUG AEROSOLS [J].
CLARK, AR ;
EGAN, M .
JOURNAL OF AEROSOL SCIENCE, 1994, 25 (01) :175-186
[5]  
CLARK AR, 2002, IN VITRO TESTING PHA, P105
[6]  
HEYDER J, 2002, BASIC PRINCIPLES PAR, P21
[7]   EFFECT OF CARDIOGENIC GAS MIXING ON ARTERIAL O-2 AND CO2 TENSIONS DURING BREATH HOLDING [J].
KELLY, SM ;
BRANCATISANO, AP ;
ENGEL, LA .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 62 (04) :1453-1459
[8]   The efficacy of slow versus faster inhalation of cromolyn sodium in protecting against allergen challenge in patients with asthma [J].
Laube, BL ;
Edwards, AM ;
Dalby, RN ;
Creticos, PS ;
Norman, PS .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1998, 101 (04) :475-483
[9]  
LAUBE BL, 1994, RESP DRUG DELIVERY, V4, P173
[10]  
NEWMAN SP, 1989, EUR RESPIR J, V2, P247