CT coronary angiography using 16 and 64 simultaneous detector rows: Intraindividual comparison

被引:47
作者
Dewey, M. [1 ]
Hoffmann, H. [1 ]
Hamm, B. [1 ]
机构
[1] Charite, Radiol, D-10117 Berlin, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2007年 / 179卷 / 06期
关键词
CT; heart; cardiac; arteries; CT angiography;
D O I
10.1055/s-2007-963112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Multislice computed tomography (MSCT) is an emerging noninvasive technique for detecting coronary artery stenoses. An intraindividual study comparing 16- and 64-slice CT coronary angiography is highly desirable but has not been performed thus far. We sought to intraindividually compare MSCT using 16. and 64 simultaneous detector rows for noninvasive coronary angiography. Materials and Methods: A total of 33 patients (23 men, 10 women) underwent MSCT coronary angiography using both 16 x 0.5 and 64 x 0.5 mm detector collimation at an interval of 2.1 +/- 0.4 years and were included in this head-to-head evaluation. A comparison of the image quality of noninvasive coronary angiography and effective radiation dose was performed. Results: The overall coronary vessel lengths visualized and the vessel lengths depicted free of motion artifacts were significantly longer using 64-slice CT compared to 16-slice CT for the left anterior descending (134 +/- 28 vs. 115 +/- 40mm and 128 +/- 34 vs. 113 +/- 41mm), left circumflex (106 +/- 31 vs. 90 +/- 39mm and 105 30 vs. 86 36 mm), and right coronary artery (153 +/- 33 mm vs. 137 +/- 47mm and 142 +/- 44mm vs. 107 61 mm) (all: p < 0.05). The overall subjective image quality on a 5-point scale (5 =maximum quality, I= minimum quality) was also significantly (p < 0.001) higher with 64-slice than with 16-slice CT for vessel contrast (4.6 +/- 0.7 vs. 4.1 1.0, p < 0.001), vessel continuity (4.8 +/- 0.6 vs. 4.5 1.1, p < 0.001), and the depiction of corona ry sidebranches (4.9 +/- 0.3 vs. 4.6 +/- 1.1, p < 0.001). The improvement in image quality was mainly due to a significant reduction in the breathhold time necessary for 64-slice CT (8.9 < 0.9sec vs. 28.5 4.6sec, p < 0.001). The amount of intravenous contrast agent required was significantly smaller with 64-slice CT (80 6 ml vs. 108 11 ml, p < 0.001), while the effective radiation dose was significantly higher for 64-slice CT (16.9 +/- 2.4 mSv vs. 12.1 +/- 2.1 mSv, p < 0.001). Conclusion: The results indicate that MSCT coronary angiography using 64 simultaneous detector rows yields higher image quality for depiction of the coronary arteries and entails a lower intravenous contrast agent amount but higher radiation exposure.
引用
收藏
页码:581 / 586
页数:6
相关论文
共 31 条
[1]   Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography [J].
Achenbach, S ;
Giesler, T ;
Ropers, D ;
Ulzheimer, S ;
Anders, K ;
Wenkel, E ;
Pohle, K ;
Kachelriess, M ;
Derlien, H ;
Kalender, WA ;
Daniel, WG ;
Bautz, W ;
Baum, U .
INVESTIGATIVE RADIOLOGY, 2003, 38 (02) :119-128
[2]  
Blobel J, 2003, ROFO-FORTSCHR RONTG, V175, P1264
[3]   Impact of coronary calcium score on diagnostic accuracy for the detection of significant coronary stenosis with multislice computed tomography angiography [J].
Cademartiri, F ;
Mollet, NR ;
Lemos, PA ;
Saia, F ;
Runza, G ;
Midiri, M ;
Krestin, GP ;
de Feyter, PJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (10) :1225-1227
[4]  
Cademartiri Filippo, 2004, Radiol Med, V107, P497
[5]   Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography [J].
Coles, DR ;
Smail, MA ;
Negus, IS ;
Wilde, P ;
Oberhoff, M ;
Karsch, KR ;
Baumbach, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (09) :1840-1845
[6]   CT coronary angiography: Examination technique, clinical results, and outlook on future developments [J].
Dewey, M. ;
Hamm, B. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (03) :246-260
[7]   Recent trends in cardiovascular imaging as reflected in RoFo [J].
Dewey, M. ;
Hamm, B. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2006, 178 (10) :953-956
[8]   Multislice CT coronary angiography: Effect of sublingual nitroglycerine on the diameter of coronary arteries [J].
Dewey, M. ;
Hoffmann, H. ;
Hamm, B. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2006, 178 (06) :600-604
[9]   Multisegment and halfscan reconstruction of 16-slice computed tomography for assessment of regional and global left ventricular myocardial function [J].
Dewey, M ;
Müller, M ;
Teige, F ;
Schnapauff, D ;
Schink, T ;
Hamm, B ;
Lembcke, A .
INVESTIGATIVE RADIOLOGY, 2006, 41 (04) :400-409
[10]   Multislice CT coronary angiography: Evaluation of an automatic vessel detection tool [J].
Dewey, M ;
Schnapauff, D ;
Laule, M ;
Lembcke, A ;
Borges, AC ;
Rutsch, W ;
Hamm, B ;
Rogalla, P .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (04) :478-483