Gadolinium-DTPA as X-ray contrast medium in clinical studies

被引:38
作者
Albrecht, T
Dawson, P
机构
[1] Free Univ Berlin, Klinikum Benjamin Franklin, Dept Radiol & Nucl Med, D-12200 Berlin, Germany
[2] Hammersmith Hosp, Imperial Coll Sch Med, Dept Imaging, London W12 0HS, England
[3] UCL, Hosp Med, Dept Radiol, London W1N 8AA, England
关键词
D O I
10.1259/bjr.73.872.11026864
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to investigate the contrast effects of gadolinium (Gd) ill patients undergoing digital subtraction angiography (DSA), intravenous urography (IVU) and CT. 15 patients attending for coeliac axis DSA (n = 5), abdominal CT ( = 5) and IVU (n = 5) were injected with 0.3 mmol kg(-1) Gd-DTPA, the maximum approved dose. For DSA and IVU, images were categorized as being of diagnostic or non-diagnostic quality. For CT, enhancement was measured in Hounsfield Units (HU). On CT, enhancement with Gd was reproducible in all cases; average peak aortic enhancement was 75 HU but duration was short. On IVU, four of five studies yielded positive pyelograms but all nephrograms were relatively poor. On DSA, all five patients had diagnostic arteriograms and four of five indirect portograms were of diagnostic quality. In all 15 cases, enhancement was weaker than that achieved with routine dosage of iodinated agents. In conclusion, Gd chelates may be clinically useful in X-ray studies under certain circumstances on patients with contraindications to iodinated agents. Higher doses than currently approved would be potentially useful.
引用
收藏
页码:878 / 882
页数:5
相关论文
共 14 条
[1]   GD-DTPA AS A CONTRAST AGENT IN CT [J].
BLOEM, JL ;
WONDERGEM, J .
RADIOLOGY, 1989, 171 (02) :578-579
[2]   Gadolinium-DTPA and gadodiamide as an alternative contrast medium for CT. [J].
Engelbrecht, V ;
Koch, JA ;
Rassek, M ;
Modder, U .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (01) :24-28
[3]  
Fobbe F, 1996, EUR RADIOL, V6, P224
[4]   Gadolinium as a CT contrast agent: Assessment in a porcine model [J].
Gierada, DS ;
Bae, KT .
RADIOLOGY, 1999, 210 (03) :829-834
[5]   ADVERSE REACTIONS TO IONIC AND NONIONIC CONTRAST-MEDIA - A REPORT FROM THE JAPANESE-COMMITTEE-ON-THE-SAFETY-OF-CONTRAST MEDIA [J].
KATAYAMA, H ;
YAMAGUCHI, K ;
KOZUKA, T ;
TAKASHIMA, T ;
SEEZ, P ;
MATSUURA, K .
RADIOLOGY, 1990, 175 (03) :621-628
[6]   GADOPENTETATE DIMEGLUMINE AS AN ALTERNATIVE CONTRAST MATERIAL FOR USE IN ANGIOGRAPHY [J].
KINNO, Y ;
ODAGIRI, K ;
ANDOH, K ;
ITOH, Y ;
TARAO, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) :1293-1294
[7]   Attenuation characteristics and application of gadolinium-DTPA in fast helical computed tomography [J].
Luboldt, W ;
DeSantis, M ;
VonSmekal, A ;
Reiser, M .
INVESTIGATIVE RADIOLOGY, 1997, 32 (11) :690-695
[8]   CLINICAL SAFETY OF GADOPENTETATE DIMEGLUMINE [J].
NELSON, KL ;
GIFFORD, LM ;
LAUBERHUBER, C ;
GROSS, CA ;
LASSER, TA .
RADIOLOGY, 1995, 196 (02) :439-443
[9]   TOLERANCE DATA OF GD-DTPA - A REVIEW [J].
NIENDORF, HP ;
DINGER, JC ;
HAUSTEIN, J ;
CORNELIUS, I ;
ALHASSAN, A ;
CLAUSS, W .
EUROPEAN JOURNAL OF RADIOLOGY, 1991, 13 (01) :15-20
[10]  
NIENDORF HP, 1994, MAGNEVIST MONOGRAPH, P21