Three-dimensional dynamic susceptibility-weighted perfusion MR imaging at 3.0 T:: Feasibility and contrast agent dose

被引:48
作者
Manka, C [1 ]
Träber, F [1 ]
Gieseke, J [1 ]
Schild, HH [1 ]
Kuhl, CK [1 ]
机构
[1] Univ Bonn, Dept Radiol, D-53105 Bonn, Germany
关键词
D O I
10.1148/radiol.2343040359
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively investigate if T2*-weighted dynamic susceptibility-weighted first-pass perfusion magnetic resonance (MR) imaging is feasible at 3.0 T and which dose of contrast agent is suitable for high-field-strength imaging. MATERIALS AND METHODS: Informed consent was obtained from all participants; study protocol was approved by the institutional review board. Study included three volunteers (two men, one woman aged 35, 39, and 52 years) and 26 patients (mean age, 49 years +/- 12.8 [standard deviation]; range, 19-76 years). Volunteers underwent 3.0-T perfusion MR imaging with 0.20, 0.10, and 0.05 mmol per kilogram body weight of gadopentetate dimeglumine; patients underwent imaging with 0.10- and 0.05-mmol doses. Perfusion MR imaging was performed with three-dimensional echo-shifted echo-planar imaging (repetition time msec/echo time msec, 14/21; isotropic 4 mm(3) voxels; 50 dynamic volumes with 30 sections each, covering entire brain at temporal resolution of 1.5 seconds per MR image). Quality of source echo-planar images and perfusion maps was assessed; perfusion maps obtained at studies with different contrast media doses were compared. Quantitative perfusion values and diagnostic sensitivity of perfusion studies with 0.10-mmol dose were compared with results with 0.05-mmol dose. Image quality scores were compared with marginal homogeneity test for multinomial variables (Mantel-Haenszel statistics for ordered categorized values). Signal-to-noise ratio and baseline signal intensity in perfusion studies were tested (Student t test for paired samples). Mean transit time (MTT), negative integral (NI), and maximum T2* effect from region-of-interest analysis were compared (one-tailed Student t test for paired samples). Quantitative data on number of gamma-fitted pixels were compared (t test for paired samples). Difference with P = .05 (t test for paired samples) was considered significant. RESULTS: Perfusion image quality was satisfactory even in areas close to skull base (47 of 52 images, minor distortions; remaining images, marked distortions). Perfusion imaging with 0.20-mmol dose caused almost complete signal cancellation during first pass, particularly in cortical gray matter, since mean maximum T2* effect of 98%, 99%, and 98% for gray matter was reached such that the accurate calculation of perfusion maps was impossible. With 0.10-mmol dose, the NI and maximum T2* effect were comparable to published data for 1.5-T perfusion imaging with 0.20- and 0.05-mmol doses, perfusion maps of sufficient diagnostic quality were obtained. For gray matter, mean maximum T2* effect was 25.4% +/- 9.8 with 0.10-mmol dose and 17.5% +/- 9.0 with 0.05-mmol dose. For white matter, mean maximum T2* effect was 15.2% +/- 4.5 with 0.10-mmol dose and 7.7% +/- 2.9 with 0.05-mmol dose. Difference in maximum signal intensity decrease was significant (P < .01). For NI, the difference between 0.10- and 0.05-mmol doses was significant: For gray matter, mean NI was 3.1 +/- 1.60 for 0.10-mmol dose and 1.56 +/- 1.16 for 0.05-mmol dose. For white matter, mean NI was 1.35 +/- 0.59 with 0.1-mmol dose and 0.59 +/- 0.30 with 0.05-mmol dose. CONCLUSION: With echo-shifted multishot echo-planar imaging, dynamic susceptibility-weighted perfusion MR imaging at high field strength is feasible without relevant image distortions. Compared with contrast agent dose for 1.5 T imaging, the dose for 3.0 T can be reduced to 0.10 mmol. (C) RSNA, 2005.
引用
收藏
页码:869 / 877
页数:9
相关论文
共 57 条
[1]  
Aichner F, 1996, J NEURAL TRANSM-SUPP, P143
[2]  
Alexander E, 2001, NEUROIMAG CLIN N AM, V11, P659
[3]   Clinical correlations of diffusion and perfusion lesion volumes in acute ischemic stroke [J].
Baird, AE ;
Lövblad, KO ;
Dashe, JF ;
Connor, A ;
Burzynski, C ;
Schlaug, G ;
Straroselskaya, I ;
Edelman, RR ;
Warach, S .
CEREBROVASCULAR DISEASES, 2000, 10 (06) :441-448
[4]  
Benner T, 2000, J MAGN RESON IMAGING, V12, P371, DOI 10.1002/1522-2586(200009)12:3<371::AID-JMRI1>3.0.CO
[5]  
2-3
[6]  
Bozzao A, 2001, AM J NEURORADIOL, V22, P1030
[7]   Perfusion-weighted dynamic susceptibility (DSC) MRI: basal ganglia hemodynamic changes after apomorphine in Parkinson's disease [J].
Brusa, L ;
Bassi, A ;
Pierantozzi, M ;
Frasca, FGS ;
Floris, R ;
Stanzione, P .
NEUROLOGICAL SCIENCES, 2002, 23 (Suppl 2) :S61-S62
[8]   MR perfusion imaging in moyamoya syndrome - Potential implications for clinical evaluation of occlusive cerebrovascular disease [J].
Calamante, F ;
Ganesan, V ;
Kirkham, FJ ;
Jan, W ;
Chong, WK ;
Gadian, DG ;
Connelly, A .
STROKE, 2001, 32 (12) :2810-2816
[9]   Cerebral hemodynamics in CADASIL before and after acetazolamide challenge assessed with MRI bolus tracking [J].
Chabriat, H ;
Pappata, S ;
Ostergaard, L ;
Clark, CA ;
Pachot-Clouard, M ;
Vahedi, K ;
Jobert, A ;
Le Bihan, D ;
Bousser, MG .
STROKE, 2000, 31 (08) :1904-1912
[10]   Perfusion-weighted magnetic resonance imaging in patients with carotid artery disease before and after carotid endarterectomy [J].
Doerfler, A ;
Eckstein, HH ;
Eichbaum, M ;
Heiland, S ;
Benner, T ;
Allenberg, JR ;
Forsting, M .
JOURNAL OF VASCULAR SURGERY, 2001, 34 (04) :587-593