Three-dimensional dynamic susceptibility-weighted perfusion MR imaging at 3.0 T:: Feasibility and contrast agent dose

被引:48
作者
Manka, C [1 ]
Träber, F [1 ]
Gieseke, J [1 ]
Schild, HH [1 ]
Kuhl, CK [1 ]
机构
[1] Univ Bonn, Dept Radiol, D-53105 Bonn, Germany
关键词
D O I
10.1148/radiol.2343040359
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively investigate if T2*-weighted dynamic susceptibility-weighted first-pass perfusion magnetic resonance (MR) imaging is feasible at 3.0 T and which dose of contrast agent is suitable for high-field-strength imaging. MATERIALS AND METHODS: Informed consent was obtained from all participants; study protocol was approved by the institutional review board. Study included three volunteers (two men, one woman aged 35, 39, and 52 years) and 26 patients (mean age, 49 years +/- 12.8 [standard deviation]; range, 19-76 years). Volunteers underwent 3.0-T perfusion MR imaging with 0.20, 0.10, and 0.05 mmol per kilogram body weight of gadopentetate dimeglumine; patients underwent imaging with 0.10- and 0.05-mmol doses. Perfusion MR imaging was performed with three-dimensional echo-shifted echo-planar imaging (repetition time msec/echo time msec, 14/21; isotropic 4 mm(3) voxels; 50 dynamic volumes with 30 sections each, covering entire brain at temporal resolution of 1.5 seconds per MR image). Quality of source echo-planar images and perfusion maps was assessed; perfusion maps obtained at studies with different contrast media doses were compared. Quantitative perfusion values and diagnostic sensitivity of perfusion studies with 0.10-mmol dose were compared with results with 0.05-mmol dose. Image quality scores were compared with marginal homogeneity test for multinomial variables (Mantel-Haenszel statistics for ordered categorized values). Signal-to-noise ratio and baseline signal intensity in perfusion studies were tested (Student t test for paired samples). Mean transit time (MTT), negative integral (NI), and maximum T2* effect from region-of-interest analysis were compared (one-tailed Student t test for paired samples). Quantitative data on number of gamma-fitted pixels were compared (t test for paired samples). Difference with P = .05 (t test for paired samples) was considered significant. RESULTS: Perfusion image quality was satisfactory even in areas close to skull base (47 of 52 images, minor distortions; remaining images, marked distortions). Perfusion imaging with 0.20-mmol dose caused almost complete signal cancellation during first pass, particularly in cortical gray matter, since mean maximum T2* effect of 98%, 99%, and 98% for gray matter was reached such that the accurate calculation of perfusion maps was impossible. With 0.10-mmol dose, the NI and maximum T2* effect were comparable to published data for 1.5-T perfusion imaging with 0.20- and 0.05-mmol doses, perfusion maps of sufficient diagnostic quality were obtained. For gray matter, mean maximum T2* effect was 25.4% +/- 9.8 with 0.10-mmol dose and 17.5% +/- 9.0 with 0.05-mmol dose. For white matter, mean maximum T2* effect was 15.2% +/- 4.5 with 0.10-mmol dose and 7.7% +/- 2.9 with 0.05-mmol dose. Difference in maximum signal intensity decrease was significant (P < .01). For NI, the difference between 0.10- and 0.05-mmol doses was significant: For gray matter, mean NI was 3.1 +/- 1.60 for 0.10-mmol dose and 1.56 +/- 1.16 for 0.05-mmol dose. For white matter, mean NI was 1.35 +/- 0.59 with 0.1-mmol dose and 0.59 +/- 0.30 with 0.05-mmol dose. CONCLUSION: With echo-shifted multishot echo-planar imaging, dynamic susceptibility-weighted perfusion MR imaging at high field strength is feasible without relevant image distortions. Compared with contrast agent dose for 1.5 T imaging, the dose for 3.0 T can be reduced to 0.10 mmol. (C) RSNA, 2005.
引用
收藏
页码:869 / 877
页数:9
相关论文
共 57 条
[11]   3D BOLUS TRACKING WITH FREQUENCY-SHIFTED BURST MRI [J].
DUYN, JH ;
VANGELDEREN, P ;
BARKER, P ;
FRANK, JA ;
MATTAY, VS ;
MOONEN, CTW .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (05) :680-687
[12]   CEREBRAL BLOOD-FLOW - ASSESSMENT WITH DYNAMIC CONTRAST-ENHANCED T2-STAR-WEIGHTED MR IMAGING AT 1.5-T [J].
EDELMAN, RR ;
MATTLE, HP ;
ATKINSON, DJ ;
HILL, T ;
FINN, JP ;
MAYMAN, C ;
RONTHAL, M ;
HOOGEWOUD, HM ;
KLEEFIELD, J .
RADIOLOGY, 1990, 176 (01) :211-220
[13]   Investigation of contrast agent dosage for perfusion-weighted MRI. [J].
Erb, G ;
Benner, T ;
Heiland, S ;
Reith, W ;
Sartor, K ;
Forsting, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (06) :599-604
[14]  
Essig M, 2002, RADIOLOGE, V42, P909, DOI 10.1007/s00117-002-0819-x
[15]   Predictors of apparent diffusion coefficient normalization in stroke patients [J].
Fiehler, J ;
Knudsen, K ;
Kucinski, T ;
Kidwell, CS ;
Alger, JR ;
Thomalla, G ;
Eckert, B ;
Wittkugel, O ;
Weiller, C ;
Zeumer, H ;
Röther, J .
STROKE, 2004, 35 (02) :514-519
[16]   Cerebral blood flow predicts lesion growth in acute stroke patients [J].
Fiehler, J ;
von Bezold, M ;
Kucinski, T ;
Knab, R ;
Eckert, B ;
Wittkugel, O ;
Zeumer, H ;
Röther, J .
STROKE, 2002, 33 (10) :2421-2425
[17]   Regional cerebral blood flow in Parkinson's disease with and without dementia [J].
Firbank, M ;
Colloby, ST ;
Burn, D ;
McKeith, IG ;
O'Brien, JT .
NEUROIMAGE, 2003, 20 (02) :1309-1319
[18]   MR CONTRAST DUE TO MICROSCOPICALLY HETEROGENEOUS MAGNETIC-SUSCEPTIBILITY - NUMERICAL SIMULATIONS AND APPLICATIONS TO CEREBRAL PHYSIOLOGY [J].
FISEL, CR ;
ACKERMAN, JL ;
BUXTON, RB ;
GARRIDO, L ;
BELLIVEAU, JW ;
ROSEN, BR ;
BRADY, TJ .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :336-347
[19]   Perfusion and molecular diffusion-weighted MR imaging of the brain:: In vivo assessment of tissue alteration in cerebral ischemia [J].
Flacke, S ;
Urbach, H ;
Block, W ;
Träber, F ;
Mürtz, P ;
Keller, E ;
Hartmann, A ;
Schild, HH .
AMINO ACIDS, 2002, 23 (1-3) :309-316
[20]  
Flacke S, 2000, JMRI-J MAGN RESON IM, V11, P250, DOI 10.1002/(SICI)1522-2586(200003)11:3<250::AID-JMRI3>3.0.CO