Piezoelectric sensors for dioxins: a biomimetic approach

被引:39
作者
Mascini, M [1 ]
Macagnano, A
Monti, D
Del Carlo, M
Paolesse, R
Chen, B
Warner, P
D'Amico, A
Di Natale, C
Compagnone, D
机构
[1] Univ Teramo, Dipartimento Sci Alimenti, I-64023 Teramo, Italy
[2] CNR, IMM, Sez Roma, I-00133 Rome, Italy
[3] Univ Roma Tor Vergata, Dipartimento Sci & Tecnol Chim, I-00133 Rome, Italy
[4] Univ Sheffield, Dept Chem, Sheffield S10 2TN, S Yorkshire, England
[5] Cranfield Univ, Inst Biosci & Technol, Silsoe MK43 0AL, Beds, England
[6] Univ Roma Tor Vergata, Dipartimento Ingn Elettr, I-00133 Rome, Italy
关键词
molecular modelling; pentapeptides; piezoelectric gas sensors; dioxins;
D O I
10.1016/j.bios.2004.06.048
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The aim of this work was to design a fast, cheap and easy to use analytical system for dioxins. Piezoelectric sensors coupled with the pentapeptides as biomimetic traps (the receptors), selective for the dioxins, were used for the realisation of this analytical system. A methodology to select specific receptors among all possible pentapeptides randomly generated was represented by the use of molecular modelling software. Three peptides called later on A, B and C (A:[N]Asn-Phe-Gln-Gly-Ile[C]; B:[N]Asn-Phe-Gln-Gly-Gln[C]; C:[N]Asn-Phe-Gln-Gly-Phe[C]), were selected and evaluated for their potential usage as artificial receptors in solid-gas analysis by using a quartz crystal microbalance (QCM) sensors array. The peptide sequences were functionalised by two terminal cysteine residues in order to achieve a covalent interaction with the QCM gold surface. A manganese-porphyrin complex and two other pentapeptides, a pentaglutamine (pentapeptide D) and a pentalysine (pentapeptide E), were used as negative control sensors. The QCM sensors (A, B and C) gave a good linearity against different sample concentrations of the 2,3,7,8-tetrachlorinated dibenzo-p-dioxin (TCDD) and a mixture of dioxins. In particular, the selectivity against 2,3,7,8-TCDD was nicely correlated to the estimated binding energy of the receptors calculcated by computational modelling. The cross-reactivity of the system was quantified using commercial polychlorinated biphenyls (PCBs) mixtures (dioxin-like compounds). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1203 / 1210
页数:8
相关论文
共 21 条
[1]  
[Anonymous], 1987, Biosensors Fundamentals and Applications
[2]  
Buchler J. W., 1978, PORPHYRINS, V1
[3]   The synthesis and screening of a combinatorial peptide library for affinity ligands for glycosylated haemoglobin [J].
Chen, B ;
Bestetti, G ;
Day, RM ;
Turner, APF .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) :779-785
[4]   Rational design of a polymer specific for microcystin-LR using a computational approach [J].
Chianella, I ;
Lotierzo, M ;
Piletsky, SA ;
Tothill, IE ;
Chen, BN ;
Karim, K ;
Turner, APF .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1288-1293
[5]   VALIDATION OF THE GENERAL-PURPOSE TRIPOS 5.2 FORCE-FIELD [J].
CLARK, M ;
CRAMER, RD ;
VANOPDENBOSCH, N .
JOURNAL OF COMPUTATIONAL CHEMISTRY, 1989, 10 (08) :982-1012
[6]   Technologies and tools for mimicking olfaction: status of the Rome "Tor Vergata" electronic nose [J].
D'Amico, A ;
Di Natale, C ;
Macagnano, A ;
Davide, F ;
Mantini, A ;
Tarizzo, E ;
Paolesse, R ;
Boschi, T .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (06) :711-721
[7]   Characterization and design of porphyrins-based broad selectivity chemical sensors for electronic nose applications [J].
Di Natale, C ;
Paolesse, R ;
Macagnano, A ;
Mantini, A ;
Goletti, C ;
D'Amico, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 52 (1-2) :162-168
[8]  
EPA Office of Water Engineering and Analysis Division, 1994, 1613 EPA OFF WAT ENG
[9]   ITERATIVE PARTIAL EQUALIZATION OF ORBITAL ELECTRONEGATIVITY - A RAPID ACCESS TO ATOMIC CHARGES [J].
GASTEIGER, J ;
MARSILI, M .
TETRAHEDRON, 1980, 36 (22) :3219-3228