A preliminary study of TiO2 deposition on NiTi by a hydrothermal method

被引:61
作者
Cheng, FT [1 ]
Shi, P
Man, HC
机构
[1] Hong Kong Polytech Univ, Dept Appl Phys, Kowloon, Hong Kong, Peoples R China
[2] Liaoning Inst Technol, Dept Mat & Chem Engn, Liaoning, Peoples R China
[3] Hong Kong Polytech Univ, Dept Ind & Syst Engn, Hong Kong, Hong Kong, Peoples R China
关键词
hydrothermal; TiO2; coating; NiTi; corrosion;
D O I
10.1016/j.surfcoat.2004.01.023
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A simple low-temperature method was employed in depositing an oxide coating on NiTi for enhancing corrosion resistance. Mechanically polished NiTi samples were pretreated in a solution containing Ti4+ ions at 60 degreesC for 8 h, followed by hydrothermal treatment at 140 degreesC for 10 h. After hydrothermal treatment, scanning electron microscopy (SEM) indicated the presence of an oxide film of approximately 200 nm on the NiTi substrate. Composition depth profiling of the oxide film by X-ray photoelectron spectroscopy (XPS) revealed that the oxide was TiO2. Thin-film X-ray diffractometry (TF-XRD) confirmed that anatase was the only crystalline phase present in the oxide film. Atomic force microscopy (AFM) recorded a mean surface roughness of 7.3 nm for the coated surface, which was of the same order as that of the polished surface (10.3 nm). Characterization of the corrosion behaviors in Hank's solution at 37 degreesC using electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization technique showed that the coated samples had a significantly higher corrosion resistance than samples prepared by mechanical polishing and chemical cleaning. The deposition method employed in the present study meets the important requirements in the surface modification of NiTi implants: (a) the substrate material should not become part of the treated layer in order to minimize the Ni content in the surface; (b) the treatment temperature should be low, preferably not exceeding 300-400 degreesC, so as not to disrupt the thermomechanical properties of the NiTi implants; (c) the process should not be a line-of-sight one to ensure a uniformly modified surface layer for implants of complex geometry. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:26 / 32
页数:7
相关论文
共 42 条
  • [1] [Anonymous], 2001, ENG MAT SER
  • [2] [Anonymous], SOL GEL SCI PHYS CHE
  • [3] *ASTM STAND, ASTM STAND B600 91 D
  • [4] *ASTM STAND G5 94, TEST METH MAK POT PO
  • [5] Badawy W. A., 1993, British Corrosion Journal, V28, P133
  • [6] ENVIRONMENTAL FACTORS AFFECTING CRITICAL PITTING POTENTIAL OF ALUMINUM
    BOHNI, H
    UHLIG, HH
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1969, 116 (07) : 906 - &
  • [7] HYDROTHERMAL EPITAXY OF HIGHLY ORIENTED TIO2 THIN-FILMS ON SILICON
    CHEN, QW
    QIAN, YT
    CHEN, ZY
    WU, WB
    CHEN, ZW
    ZHOU, GE
    ZHANG, YH
    [J]. APPLIED PHYSICS LETTERS, 1995, 66 (13) : 1608 - 1610
  • [8] NiTi cladding on stainless steel by TIG surfacing process Part I. Cavitation erosion behavior
    Cheng, FT
    Lo, KH
    Man, HC
    [J]. SURFACE & COATINGS TECHNOLOGY, 2003, 172 (2-3) : 308 - 315
  • [9] NiTi cladding on stainless steel by TIG surfacing process Part II. Corrosion behavior
    Cheng, FT
    Lo, KH
    Man, HC
    [J]. SURFACE & COATINGS TECHNOLOGY, 2003, 172 (2-3) : 316 - 321
  • [10] Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks' solution
    Cisse, O
    Savadogo, O
    Wu, M
    Yahia, L
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 61 (03): : 339 - 345