A method to establish the relationship between CT number and effective density for therapeutic radiations is proposed. We approximated body tissues to mixtures of muscle, air, fat and bone. Consequently, the relationship can be calibrated only with a CT scan of their substitutes, for which we chose water, air, ethanol and potassium phosphate solution, respectively. With simple and specific corrections for non-equivalencies of the substitutes, a calibration accuracy of 1% will be achieved. We tested the calibration method with some biological materials to verify that the proposed method would offer the accuracy, simplicity and specificity required for a standard in radiotherapy treatment planning, in particular with heavy charged particles.
引用
收藏
页码:1053 / 1064
页数:12
相关论文
共 19 条
[1]  
[Anonymous], 1989, TISS SUBST RAD DOS M
[2]  
[Anonymous], 1993, 49 ICRU
[3]   TREATMENT PLANNING FOR HEAVY-ION RADIOTHERAPY [J].
CHEN, GTY ;
SINGH, RP ;
CASTRO, JR ;
LYMAN, JT ;
QUIVEY, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1979, 5 (10) :1809-1819
[4]   AN ELECTRON-DENSITY CALIBRATION PHANTOM FOR CT-BASED TREATMENT PLANNING COMPUTERS [J].
CONSTANTINOU, C ;
HARRINGTON, JC ;
DEWERD, LA .
MEDICAL PHYSICS, 1992, 19 (02) :325-327
[5]  
ICRP, 1975, ICRP PUBL, V23
[6]  
ICRU, 1992, ICRU Report 46
[7]  
ICRU, 1984, 37 ICRU
[8]  
*IEC, 1994, 6122326 IEC
[9]   X-RAY ATTENUATION COEFFICIENTS OF ELEMENTS AND MIXTURES [J].
JACKSON, DF ;
HAWKES, DJ .
PHYSICS REPORTS-REVIEW SECTION OF PHYSICS LETTERS, 1981, 70 (03) :169-233
[10]  
Jäkel O, 2001, MED PHYS, V28, P701, DOI 10.1118/1.1357455