Macromolecular MRI contrast agents with small dendrimers: Pharmacokinetic differences between sizes and cores

被引:209
作者
Kobayashi, H
Kawamoto, S
Jo, SK
Bryant, HL
Brechbiel, MW
Star, RA
机构
[1] NCI, Metab Branch, Canc Res Ctr, NIH, Bethesda, MD 20892 USA
[2] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD USA
[3] NIH, Warren Grant Magnuson Clin Ctr, Lab Diagnost Radiol Res, Bethesda, MD 20892 USA
[4] NCI, Radioimmune & Inorgan Chem Sect, Radiat Oncol Branch, NIH, Bethesda, MD 20892 USA
[5] NIDDKD, Renal Diagnost & Therapeut Unit, NIH, Bethesda, MD 20892 USA
关键词
D O I
10.1021/bc025633c
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Large macromolecular MRI contrast agents with albumin or dendrimer cores are useful for imaging blood vessels. However, their prolonged retention is a major limitation for clinical use. Although smaller dendrimer-based MRI contrast agents are more quickly excreted by the kidneys, they are also able to visualize vascular structures better than Gd-DTPA due to less extravasation. Additionally, unlike Gd-DTPA, they transiently accumulate in renal tubules and thus also can be used to visualize renal structural and functional damage. However, these dendrimer agents are retained in the body for a prolonged time. The purpose of this study was to obtain information from which a macromolecular dendrimer-based MRI contrast agents feasible for use in further clinical studies could be chosen. Six small dendrimer-based MRI contrast agents were synthesized, and their pharmacokinetics, whole-body retention, and dynamic MRI were evaluated in mice to determine an optimal agent in comparison to Gd-[DTPA]-dimeglumine. Diaminobutane (DAB) dendrimer-based agents cleared more rapidly from the body than polyamidoamine (PAMAM) dendrimer-based agents with the same numbers of branches. Smaller dendrimer conjugates were more rapidly excreted from the body than the larger dendrimer conjugates. Since PAMAM-G2, DAB-G3, and DAB-G2 dendrimer-based contrast agents showed relatively rapid excretion, these three conjugates might be acceptable for use in further clinical applications.
引用
收藏
页码:388 / 394
页数:7
相关论文
共 33 条
[1]   BORONATED STARBURST DENDRIMER MONOCLONAL-ANTIBODY IMMUNOCONJUGATES - EVALUATION AS A POTENTIAL DELIVERY SYSTEM FOR NEUTRON-CAPTURE THERAPY [J].
BARTH, RF ;
ADAMS, DM ;
SOLOWAY, AH ;
ALAM, F ;
DARBY, MV .
BIOCONJUGATE CHEMISTRY, 1994, 5 (01) :58-66
[2]   Evaluation of the effects of intravascular MR contrast media (gadolinium dendrimer) on 3D time of flight magnetic resonance angiography of the body [J].
Bourne, MW ;
Margerun, L ;
Hylton, N ;
Campion, B ;
Lai, JJ ;
Derugin, N ;
Higgins, CB .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (02) :305-310
[3]  
Bryant LH, 1999, JMRI-J MAGN RESON IM, V9, P348, DOI 10.1002/(SICI)1522-2586(199902)9:2<348::AID-JMRI30>3.0.CO
[4]  
2-J
[5]   Focal malignant hepatic lesions: MR imaging enhanced with gadolinium benzyloxypropionictetra-acetate (BOPTA) - Preliminary results of phase II clinical application [J].
Caudana, R ;
Morana, G ;
Pirovano, GP ;
Nicoli, N ;
Portuese, A ;
Spinazzi, A ;
DiRito, R ;
Pistolesi, GF .
RADIOLOGY, 1996, 199 (02) :513-520
[6]   Monoclonal antibody-dendrimer conjugates enable radiolabeling of antibody with markedly high specific activity with minimal loss of immunoreactivity [J].
Kobayashi, H ;
Sato, N ;
Saga, T ;
Nakamoto, Y ;
Ishimori, T ;
Toyama, S ;
Togashi, K ;
Konishi, J ;
Brechbiel, MW .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (09) :1334-1339
[7]   Evaluation of the in vivo biodistribution of indium-111 and yttrium-88 labeled dendrimer-1B4M-DTPA and its conjugation with anti-Tac monoclonal antibody [J].
Kobayashi, H ;
Wu, CC ;
Kim, MK ;
Paik, CH ;
Carrasquillo, JA ;
Brechbiel, MW .
BIOCONJUGATE CHEMISTRY, 1999, 10 (01) :103-111
[8]   Novel liver macromolecular MR contrast agent with a polypropylenimine diaminobutyl dendrimer core: Comparison to the vascular MR contrast agent with the polyamidoamine dendrimer core [J].
Kobayashi, H ;
Kawamoto, S ;
Saga, T ;
Sato, N ;
Hiraga, A ;
Ishimori, T ;
Akita, Y ;
Mamede, MH ;
Konishi, J ;
Togashi, K .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) :795-802
[9]   Renal tubular damage detected by dynamic micro-MRI with a dendrimer-based magnetic resonance contrast agent [J].
Kobayashi, H ;
Kawamoto, S ;
Jo, SK ;
Sato, N ;
Saga, T ;
Hiraga, A ;
Konishi, J ;
Hu, S ;
Togashi, K ;
Brechbiel, MW ;
Star, RA .
KIDNEY INTERNATIONAL, 2002, 61 (06) :1980-1985
[10]  
Kobayashi H, 2000, J NUCL MED, V41, P755