Solid phase extraction method for selective determination of Pb(II) in water samples using 4-(4-methoxybenzylidenimine) thiophenole

被引:55
作者
Ghaedi, M.
Montazerozohori, M.
Soylak, M. [1 ]
机构
[1] Erciyes Univ, Dept Chem, TR-38039 Kayseri, Turkey
[2] Univ Yasuj, Dept Chem, Yasuj 75914353, Iran
关键词
4-(4-methoxybenzylidenimine) thiophenole; lead; surfactant coated alumina; atomic absorption spectrometry; solid phase extraction;
D O I
10.1016/j.jhazmat.2006.08.033
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A sensitive and selective extractive preconcentration procedure for the determination of traces of lead in water samples has been developed. An alumina-sodium dodecyl sulfate (SDS) coated modified with 4-(4-methoxybenzylidenimine) thiophenole (MBITP) was used for preconcentration and determination of Pb(II) by flame atomic absorption spectrometry. Lead was adsorbed quantitatively on modified column due to its complexation with MBITP and quantitatively eluted using 5 mL 1 mol L-1 nitric acid in acetone. The effects of parameters such as pH, amount of solid phase, amount of MBITP, flow rate, type and concentration of eluting agent were examined. The effect of interfering ions on the determination of Pb(11) was also investigated. The response of proposed method is linear in the concentration range 0.05-1.2 mu g mL(-1) of Pb(II). The limit of detections (3S.D.(b)/m, n = 4) and relative standard deviations (n = 11) are 1.6 ng mL(-1) and 0.9%, respectively. The presented procedure was successfully applied for determination of lead content in real samples such as river, spring, waste and drinking water. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:368 / 373
页数:6
相关论文
共 36 条
[1]  
Ana O.D.S., 2004, J BRAZIL CHEM SOC, V15, P96
[2]   Application of ram horn powder (RHP) for the preconcentration and determination of copper in various samples by flame atomic absorption spectrometry [J].
Baytak, S ;
Türker, AR .
JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 61 (05) :483-489
[3]  
Choi JM, 2006, B KOREAN CHEM SOC, V27, P563
[4]   Automatic flow procedure based on multicommutation exploiting liquid-liquid extraction for spectrophotometric lead determination in plant material [J].
Comitre, ALD ;
Reis, BF .
TALANTA, 2005, 65 (04) :846-852
[5]   On-line preconcentration with different solid adsorbents for lead determination [J].
da Silva, JBB ;
Quináia, SP ;
Rollemberg, MCE .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (7-8) :657-660
[6]   Immobilized salen (N,N′-bis (salicylidene) ethylenediamine) as a complexing agent for on-line sorbent extraction/preconcentration and flow injection-flame atomic absorption spectrometry [J].
Dadfarnia, S ;
Shabani, AMH ;
Tamaddon, F ;
Rezaei, M .
ANALYTICA CHIMICA ACTA, 2005, 539 (1-2) :69-75
[7]  
Dadfarnia S, 2002, B KOREAN CHEM SOC, V23, P545
[8]  
De A.K., 1996, ENVIRON CHEM, P263
[9]   Flow injection solid phase extraction with Chromosorb 102:: determination of lead in soil and waters by flame atomic absorption spectrometry [J].
Elçi, L ;
Arslan, Z ;
Tyson, JF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) :1109-1116
[10]   On-line preconcentration system for lead(II) determination in waste water by atomic absorption spectrometry using active carbon loaded with pyrogallol red [J].
Ensafi, AA ;
Khayamian, T ;
Karbasi, MH .
ANALYTICAL SCIENCES, 2003, 19 (06) :953-956