On-line preconcentration with different solid adsorbents for lead determination

被引:27
作者
da Silva, JBB
Quináia, SP
Rollemberg, MCE [1 ]
机构
[1] UEM, Dept Quim, BR-87020900 Marinaga, PR, Brazil
[2] Unictr, Dept Quim, BR-85000000 Guarapuava, PR, Brazil
[3] UFMG, Dept Quim, BR-31270901 Belo Horizonte, MG, Brazil
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2001年 / 369卷 / 7-8期
关键词
D O I
10.1007/s002160100767
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line column preconcentration method based on the combined use of ammonium O,O-diethyldithiophosphate and activated carbon or polyurethane foam as adsorbents has been developed for the determination of Pb in water samples. The complexed Pb was eluted with ethanol and determined by flame atomic absorption spectrometry, The optimum preconcentration conditions an given for each adsorbent. The enrichment factors were 63 and 294, and the detection limits (3 sigma) 3 mu gL(-1) and 0.8 mug L-1, respectively, for the carbon and foam systems. When the optimized procedures were applied to the determination of Pb in water samples the recovery efficiency was > 96%.
引用
收藏
页码:657 / 660
页数:4
相关论文
共 22 条
[1]   COLUMN SOLID-PHASE EXTRACTION AS PRECONCENTRATION METHOD FOR TRACE-ELEMENT DETERMINATION IN OXALIC-ACID BY ATOMIC-ABSORPTION SPECTROMETRY AND INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
ALEXANDROVA, A ;
ARPADJAN, S .
ANALYTICA CHIMICA ACTA, 1995, 307 (01) :71-77
[2]   Sorption of arsenic, bismuth, mercury, antimony, selenium and tin on dithiocarbamate loaded polyurethane foam as a preconcentration method for their determination in water samples by simultaneous inductively coupled plasma atomic emission spectrometry and electrothermal atomic absorption spectrometry [J].
Arpadjan, S ;
Vuchkova, L ;
Kostadinova, E .
ANALYST, 1997, 122 (03) :243-246
[3]  
Aydemir T, 1996, ANAL LETT, V29, P351, DOI 10.1080/00032719608000403
[4]  
BODE H, 1962, Z ANAL CHEM, V185, P179
[5]   LABILE/INERT METAL SPECIES IN AQUATIC HUMIC SUBSTANCES - AN ION-EXCHANGE STUDY [J].
BURBA, P .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (04) :301-311
[6]  
BURBA P, 1992, FRESEN J ANAL CHEM, V324, P167
[7]   On-line preconcentration system for flame atomic absorption spectrometry using unloaded polyurethane foam: determination of zinc in waters and biological materials [J].
Cassella, RJ ;
Bitencourt, DT ;
Branco, AG ;
Ferreira, SLC ;
de Jesus, DS ;
de Carvalho, MS ;
Santelli, RE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (11) :1749-1753
[8]   FLAME ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF CADMIUM IN BIOLOGICAL SAMPLES USING A PRECONCENTRATION FLOW SYSTEM WITH AN ACTIVATED CARBON COLUMN AND DITHIZONE AS A CHELATING AGENT [J].
DEPENA, YP ;
GALLEGO, M ;
VALCARCEL, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (06) :691-696
[9]   EXTRACTION, SEPARATION, AND DETERMINATION OF NICKEL AND BISMUTH WITH 1-(2-PYRIDYLAZO)-2-NAPHTHOL IN AQUEOUS THIOCYANATE MEDIA [J].
ELNEMMA, EM ;
FARAG, AB .
SEPARATION SCIENCE AND TECHNOLOGY, 1994, 29 (08) :1043-1054
[10]  
FANG ZL, 1991, SPECTROCHIM ACTA REV, V14, P235