Flow based immuno/bioassay and trends in micro-immuno/biosensors

被引:47
作者
Hartwell, Supaporn Kradtap [1 ,2 ]
Grudpan, Kate [1 ,2 ]
机构
[1] Chiang Mai Univ, Fac Sci, Dept Chem, Chiang Mai 50200, Thailand
[2] Chiang Mai Univ, Fac Sci, Ctr Innovat Chem, Chiang Mai 50200, Thailand
关键词
Flow injection; Immunoassay; Bioassay; Sensors; SEQUENTIAL INJECTION-ANALYSIS; DISPOSABLE ELECTROCHEMICAL IMMUNOSENSOR; CAPILLARY ENZYME-IMMUNOASSAY; QUARTZ-CRYSTAL MICROBALANCE; LAB-ON-VALVE; QUANTUM DOTS; CARCINOEMBRYONIC ANTIGEN; CHEMILUMINESCENT IMMUNOSENSOR; IMMUNOAFFINITY EXTRACTION; QUANTITATIVE DETECTION;
D O I
10.1007/s00604-010-0333-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The term immuno/bioassay refers to analytical techniques that utilize the specific molecular recognition between antibodies and antigens or between biomolecules and specific receptors. Features such as high selectivity and low sample consumption make them very useful for analysis of samples with complex matrices. However, immuno/bioassays involve time-consuming (multi-step) operations which usually consist of steps of multiple incubation and washing. These are tedious and may result in large errors. Automatted immuno/bioassay systems can ease and shorten these processes and thus are highly beneficial. The hyphenation of flow-based techniques (i.e. flow injection related techniques and micro-fluidic systems) with immuno/bioassay protocols paves a new way for performing such assays. Compared to conventional micro-plate formats, flow-based immuno/bioassays can reduce the time needed for analysis, the volumes of samples and reagents consumed, and the need for trained personnel. In order to transform immuno/bioassays from conventional to flow-based formats, the solid surfaces used for the immobilization step has to be changed in order to meet the specific requirements of flow systems. To further develop the on-site analytical systems in micro-fluidic platforms, improvements in detection methods are necessary for high-sensitivity and rapid measurement. This review overviews the advantages and disadvantages of flow-based immuno/bioassay formats, the various types of solid surfaces for immobilization, and the methods of detection. Trends to improve sensitivity, speed and robustness are emphasized.
引用
收藏
页码:201 / 220
页数:20
相关论文
共 233 条
  • [1] Highly sensitive flow-injection immunoassay system for rapid detection of bacteria
    Abdel-Hamid, I
    Ivnitski, D
    Atanasov, P
    Wilkins, E
    [J]. ANALYTICA CHIMICA ACTA, 1999, 399 (1-2) : 99 - 108
  • [2] A Label-Free Porous Alumina Interferometric Immunosensor
    Alvarez, Sara D.
    Li, Chang-Peng
    Chiang, Casey E.
    Schuller, Ivan K.
    Sailor, Michael J.
    [J]. ACS NANO, 2009, 3 (10) : 3301 - 3307
  • [3] Molecularly imprinted polymers in pseudoimmunoassay
    Ansell, RJ
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 804 (01): : 151 - 165
  • [4] Controlled microfluidic interfaces
    Atencia, J
    Beebe, DJ
    [J]. NATURE, 2005, 437 (7059) : 648 - 655
  • [5] A PMMA microcapillary quantum dot linked immunosorbent assay (QLISA)
    Babu, Sundar
    Mohapatra, Sakya
    Zubkov, Leonid
    Murthy, Sreekant
    Papazoglou, Elisabeth
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 24 (12) : 3467 - 3474
  • [6] Microfluidic immunosensor systems
    Bange, A
    Halsall, HB
    Heineman, WR
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) : 2488 - 2503
  • [7] Cys-diabody Quantum Dot Conjugates (ImmunoQdots) for Cancer Marker Detection
    Barat, Bhaswati
    Sirk, Shannon J.
    McCabe, Katelyn E.
    Li, Jianqing
    Lepin, Eric J.
    Remenyi, Roland
    Koh, Ai Leen
    Olafsen, Tove
    Gambhir, Sanjiv S.
    Weiss, Shimon
    Wu, Anna M.
    [J]. BIOCONJUGATE CHEMISTRY, 2009, 20 (08) : 1474 - 1481
  • [8] Zeptomole-detecting biosensor for alkaline phosphatase in an electrochemical immunoassay for 2,4-dichlorophenoxyacetic acid
    Bauer, CG
    Eremenko, AV
    EhrentreichForster, E
    Bier, FF
    Makower, A
    Halsall, HB
    Heineman, WR
    Scheller, FW
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (15) : 2453 - 2458
  • [9] Use of cotinine immunoassay test strips for preclassifying urine samples from smokers and nonsmokers prior to analysis by LC-MS-MS
    Bernert, JT
    Harmon, TL
    Sosnoff, CS
    McGuffey, JE
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2005, 29 (08) : 814 - 818
  • [10] Development of a heterogeneous chemiluminescent flow immunoassay for DDT and related compounds
    Botchkareva, AE
    Fini, F
    Eremin, SA
    Mercader, JV
    Montoya, A
    Girotti, S
    [J]. ANALYTICA CHIMICA ACTA, 2002, 453 (01) : 43 - 52