Electrochemical quartz crystal microbalance in modern corrosion research - Study of the pretreatment of galvanized steel

被引:15
作者
Stellnberger, KH [1 ]
Wolpers, M [1 ]
Fili, T [1 ]
Reinartz, C [1 ]
Paul, T [1 ]
Stratmann, M [1 ]
机构
[1] Lehrstuhl Korros & Oberflachentech, D-91058 Erlangen, Germany
来源
FARADAY DISCUSSIONS | 1997年 / 107卷
关键词
D O I
10.1039/a703236f
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The electrochemical quartz crystal microbalance (EQCM) is applied in order to study the technical pretreatment processes of galvanized steel such as alkaline cleaning, chromating End phosphating in modern trication solutions. The mass change associated with these reactions is monitored in situ under conditions which are very similar to those of a coil-coating line. It is shown that cleaning of the zinc surface in an alkaline cleaning solution is a two-step process: removal of the zinc oxide layer by a chemical dissolution followed by electrochemical dissolution of zinc, the rate of which is controlled by the diffusion of zincate ions into the electrolyte. During phosphating of the sample, three subsequent steps are observed: zinc dissolution during the first seconds followed by precipitation of a phosphate layer and then cementation of Ni, which leads again to increasing dissolution of the base material.
引用
收藏
页码:307 / 322
页数:16
相关论文
共 28 条
[1]   ANODIC DISSOLUTION OF ZINC IN ALKALINE SOLUTIONS [J].
ARMSTRONG, RD ;
BULMAN, GM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1970, 25 (01) :121-+
[2]   AN IMPROVED QUARTZ MICROBALANCE - APPLICATIONS TO THE ELECTROCRYSTALLIZATION AND ELECTRODISSOLUTION OF NICKEL [J].
BENJE, M ;
EIERMANN, M ;
PITTERMANN, U ;
WEIL, KG .
BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1986, 90 (05) :435-439
[3]   IN-SITU RAMAN-STUDY OF THE CORROSION OF ZINC-COATED STEEL IN THE PRESENCE OF CHLORIDE .1. CHARACTERIZATION AND STABILITY OF ZINC CORROSION PRODUCTS [J].
BERNARD, MC ;
HUGOTLEGOFF, A ;
PHILLIPS, N .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1995, 142 (07) :2162-2167
[4]  
BISHOP CV, 1980, GALVANOTECHNIK, V71, P1199
[5]   EXPERIMENTAL ASPECTS OF USE OF THE QUARTZ CRYSTAL MICROBALANCE IN SOLUTION [J].
BRUCKENSTEIN, S ;
SHAY, M .
ELECTROCHIMICA ACTA, 1985, 30 (10) :1295-1300
[6]  
Buttry D., 1991, ELECTROANALYTICAL CH, V17
[7]  
DETTNER W, 1963, HDB GALVANOTECHNIK
[8]  
FILI T, IN PRESS
[9]   IMPEDANCE ANALYSIS OF THE QUARTZ MICRO-BALANCE SIGNAL [J].
FRUBOSE, C ;
DOBLHOFER, K ;
SOARES, DM .
BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1993, 97 (03) :475-478
[10]  
GRAUER R, 1972, CORROS SCI, V12, P612