Modified electrode voltammetric sensors for trace metals in environmental samples

被引:17
作者
Brett, CMA [1 ]
Fungaro, DA
机构
[1] Univ Coimbra, Dept Quim, P-3000 Coimbra, Portugal
[2] IPEN, Div Quim Ambiental MQA, BR-05508900 Sao Paulo, SP, Brazil
关键词
polymer-modified electrodes; trace metal analysis; batch injection analysis; environmental monitoring;
D O I
10.1590/S0103-50532000000300017
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Nafion-modified mercury thin film electrodes have been investigated for the analysis of trace metals in environmental samples of waters and effluent by batch injection analysis with square wave anodic stripping voltammetry. The method, involving injection over the detector electrode of untreated samples of volume of the order of 50 microlitres has fast response, blocking and fouling of the electrode is minimum as shown by studies with surface-active components. Comparison is made between glassy carbon substrate electrodes and carbon fibre microelectrode array substrates, the latter leading to a small sensitivity enhancement. Application to analysis. of river water and industrial effluent for labile zinc, cadmium, lead and copper ions is demonstrated in collected samples and after acid digestion.
引用
收藏
页码:298 / 303
页数:6
相关论文
共 15 条
[1]  
Brett CMA, 1999, ELECTROANAL, V11, P1013, DOI 10.1002/(SICI)1521-4109(199910)11:14<1013::AID-ELAN1013>3.0.CO
[2]  
2-Y
[3]   Poly(ester sulphonic acid) coated mercury thin film electrodes: characterization and application in batch injection analysis stripping voltammetry of heavy metal ions [J].
Brett, CMA ;
Fungaro, DA .
TALANTA, 2000, 50 (06) :1223-1231
[4]   Novel polymer-modified electrodes for batch injection sensors and application to environmental analysis [J].
Brett, CMA ;
Fungaro, DA ;
Morgado, JM ;
Gil, MH .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 468 (01) :26-33
[5]   Anodic stripping voltammetry of trace metals by batch injection analysis [J].
Brett, CMA ;
Brett, AMO ;
Tugulea, L .
ANALYTICA CHIMICA ACTA, 1996, 322 (03) :151-157
[6]   Nafion-coated mercury thin film electrodes for batch-injection analysis with anodic stripping voltammetry [J].
Brett, CMA ;
Brett, AMO ;
Matysik, FM ;
Matysik, S ;
Kumbhat, S .
TALANTA, 1996, 43 (11) :2015-2022
[7]   AMPEROMETRIC BATCH INJECTION-ANALYSIS - THEORETICAL ASPECTS OF CURRENT TRANSIENTS AND COMPARISON WITH WALL-JET ELECTRODES IN CONTINUOUS-FLOW [J].
BRETT, CMA ;
BRETT, AMO ;
MITOSERIU, LC .
ELECTROANALYSIS, 1995, 7 (03) :225-229
[8]  
BRETT CMA, 1993, ELECTROCHEMISTRY PRI, pCH8
[9]   COMPARATIVE-STUDY OF POLYMER-COATED MERCURY FILM ELECTRODES FOR VOLTAMMETRIC ANALYSIS OF LEAD AND CADMIUM IN THE PRESENCE OF SURFACTANTS [J].
DAM, MER ;
THOMSEN, KN ;
PICKUP, PG ;
SCHRODER, KH .
ELECTROANALYSIS, 1995, 7 (01) :70-78
[10]   Microelectrode arrays: application in batch-injection analysis [J].
Fungaro, DA ;