Optimization of sol-gel based fibre-optic cholinesterase biosensor for the determination of organophosphorus pesticides

被引:15
作者
Tsai, HC [1 ]
Doong, RA [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Atom Sci, Hsinchu 30043, Taiwan
关键词
acetylcholinesterase; pH sensitive fluorescent indicator; sol-gel immobilization; fiber-optic; biosensor; organophosphorus pesticides;
D O I
10.2166/wst.2000.0580
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A sol-gel based fiber-optic biosensor with acetylcholinasterase as the biorecognition element has been developed for the rapid determination of organophosphorus pesticides. Nine fluorescent indicators, acridine, acridine orange, neutral red, DAPI, rhodamine B, fluorescein, umbelliferone, FITC on celite and FITC-dextran, have been examined to optimize the fiber-optic system. Results showed that acridine and FITCs ware sensitive to the change of pH value caused by the enzyme-substrate catalysis reaction. However, the sensitivity of acridine was 260 times lower than that of FITCs. Higher toxicity of acridine to acetylcholinesterase than FITC was also observed. Moreover, the high-molecular-weight FITC-dextran showed low leakage rate when immobilizing using sol-gel technology, showing that the FITC-dextran was a suitable pH sensitive fluorescent indicator for the OPPs biosensor. The response of the fiber-optic biosensor to the substrate, acetylcholine, was highly reproducible (RSD=3.5%). A good linearity of acetylcholina in the range from 0.5 to 20 mM was also obtained (R-2=0.98). Furthermore, a 30% inhibition can be achieved in 30min when 152 ppb paraoxon was added into the system. The results show the possibility for real-time determination of organophosphorus pesticides by using the biosensor developed in this study.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 10 条
[1]   Fibre-optic pesticide biosensor based on covalently immobilized acetylcholinesterase and thymol blue [J].
Andres, RT ;
Narayanaswamy, R .
TALANTA, 1997, 44 (08) :1335-1352
[2]   BUTYRYLCHOLINE ENZYME SENSOR FOR DETERMINING ORGANOPHOSPHORUS INHIBITORS [J].
CAMPANELLA, L ;
ACHILLI, M ;
SAMMARTINO, MP ;
TOMASSETTI, M .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1991, 26 (02) :237-249
[3]   Chemometric methods for the development of a biosensor system and the evaluation of inhibition studies with solutions and mixtures of pesticides and heavy metals .1. Development of an enzyme electrodes system for pesticide and heavy metal screening using selected chemometric methods [J].
Danzer, T ;
Schwedt, G .
ANALYTICA CHIMICA ACTA, 1996, 318 (03) :275-286
[4]  
DIAZ AN, 1997, SENSOR ACTUAT B-CHEM, V38, P426
[5]   PESTICIDE-SENSITIVE ISFET BASED ON ENZYME-INHIBITION [J].
DUMSCHAT, C ;
MULLER, H ;
STEIN, K ;
SCHWEDT, G .
ANALYTICA CHIMICA ACTA, 1991, 252 (1-2) :7-9
[6]   ENCAPSULATION OF PROTEINS IN TRANSPARENT POROUS SILICATE-GLASSES PREPARED BY THE SOL-GEL METHOD [J].
ELLERBY, LM ;
NISHIDA, CR ;
NISHIDA, F ;
YAMANAKA, SA ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
SCIENCE, 1992, 255 (5048) :1113-1115
[7]  
GUILBAULT GG, 1973, PRACTICAL FLUROESCEN, P599
[8]   DETERMINATION OF ORGANOPHOSPHORUS INSECTICIDES WITH A CHOLINE ELECTROCHEMICAL BIOSENSOR [J].
PALLESCHI, G ;
BERNABEI, M ;
CREMISINI, C ;
MASCINI, M .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) :513-517
[9]   ACETYLCHOLINESTERASE FIBEROPTIC BIOSENSOR FOR DETECTION OF ANTICHOLINESTERASES [J].
ROGERS, KR ;
CAO, CJ ;
VALDES, JJ ;
ELDEFRAWI, AT ;
ELDEFRAWI, ME .
FUNDAMENTAL AND APPLIED TOXICOLOGY, 1991, 16 (04) :810-820
[10]   FIBEROPTIC REMOTE DETECTION OF PESTICIDES AND RELATED INHIBITORS OF THE ENZYME ACETYLCHOLINE ESTERASE [J].
TRETTNAK, W ;
REININGER, F ;
ZINTERL, E ;
WOLFBEIS, OS .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 11 (1-3) :87-93