PESTICIDE-SENSITIVE ISFET BASED ON ENZYME-INHIBITION

被引:66
作者
DUMSCHAT, C [1 ]
MULLER, H [1 ]
STEIN, K [1 ]
SCHWEDT, G [1 ]
机构
[1] TECH UNIV CLAUSTHAL,INST ANORGAN & ANALYT CHEM,W-3392 CLAUSTHAL ZELLERFE,GERMANY
关键词
POTENTIOMETRY; BIOSENSORS; ENZYME INHIBITION; ION-SENSITIVE FIELD EFFECT TRANSISTORS; PESTICIDES; WATER;
D O I
10.1016/0003-2670(91)87189-E
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple method for an enzyme inhibition test is described. The decrease in enzyme activity after incubation in a solution of dichlorvos as inhibitor is detected potentiometrically. The enzyme acetylcholinesterase is immobilized onto the pH-sensitive gate area of an ISFET. Such a biosensor is able to detect dichlorvos in water in the concentration range from 0.3 to 1.2 mg l-1 without preconcentration.
引用
收藏
页码:7 / 9
页数:3
相关论文
共 12 条
[1]   PENICILLIN-G SENSOR BASED ON PENICILLIN AMIDASE COUPLED TO A FIELD-EFFECT TRANSISTOR [J].
BRAND, U ;
SCHEPER, T ;
SCHUGERL, K .
ANALYTICA CHIMICA ACTA, 1989, 226 (01) :87-97
[2]   ENCAPSULATION OF CHEMICALLY SENSITIVE FIELD-EFFECT TRANSISTORS WITH PHOTOCURABLE EPOXY-RESINS [J].
DUMSCHAT, C ;
MULLER, H ;
RAUTSCHEK, H ;
TIMPE, HJ ;
HOFFMANN, W ;
PHAM, MT ;
HULLER, J .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 2 (04) :271-276
[3]   DETECTION OF ORGANOPHOSPHOROUS PESTICIDES WITH AN IMMOBILIZED CHOLINESTERASE ELECTRODE [J].
DURAND, P ;
NICAUD, JM ;
MALLEVIALLE, J .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1984, 8 (03) :112-117
[4]   MICRO-ENZYME FIELD-EFFECT TRANSISTOR SENSOR USING DIRECT COVALENT BONDING OF UREASE [J].
GARDIES, F ;
JAFFREZICRENAULT, N ;
MARTELET, C ;
PERROT, H ;
VALLETON, JM ;
ALEGRET, S .
ANALYTICA CHIMICA ACTA, 1990, 231 (02) :305-308
[5]  
Goodson L H, 1976, Methods Enzymol, V44, P647
[6]   GLUCOSE SENSOR BASED ON A FIELD-EFFECT TRANSISTOR WITH A PHOTOLITHOGRAPHICALLY PATTERNED GLUCOSE-OXIDASE MEMBRANE [J].
HANAZATO, Y ;
NAKAKO, M ;
MAEDA, M ;
SHIONO, S .
ANALYTICA CHIMICA ACTA, 1987, 193 :87-96
[7]  
HERZSPRUNG L, 1990, WASSER, V74, P339
[8]  
HINTSCHE R, 1989, ANAL LETT, V22, P2175
[9]   EXCHANGEABLE IMMOBILIZED ENZYME REACTOR FOR ENZYME-INHIBITION TESTS IN FLOW-INJECTION ANALYSIS USING A MAGNETIC DEVICE - DETERMINATION OF PESTICIDES IN DRINKING-WATER [J].
KINDERVATER, R ;
KUNNECKE, W ;
SCHMID, RD .
ANALYTICA CHIMICA ACTA, 1990, 234 (01) :113-117
[10]   FLOW-INJECTION DETERMINATION OF PARAOXON BY INHIBITION OF IMMOBILIZED ACETYLCHOLINESTERASE [J].
LEONGONZALEZ, ME ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1990, 236 (02) :267-272