In vivo validation of the time domain velocity measurement technique of blood flow in human fetuses

被引:8
作者
Alcazar, JL [1 ]
Laparte, C [1 ]
机构
[1] Univ Navarra Clin, Dept Obstet & Gynecol, Sch Med, E-31008 Pamplona, Spain
关键词
time domain processing; Doppler; blood flow velocity; fetus;
D O I
10.1016/S0301-5629(97)00234-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Time domain ultrasonography is an alternative to Doppler analysis of blood flow direction and velocity, The time domain technique uses timing information between successive echo pulses to measure flow velocities directly through a color display map, This study was undertaken to validate this technique for measuring peak systolic velocity compared to the pulsed-wave Doppler method in human fetuses. Twenty normally developing fetuses were included in the study, The fetal abdominal aorta and the umbilical artery were studied in 12 and eight cases, respectively, We first estimated how velocity using time domain ultrasonography and inmediately after pulsed Doppler was used. The intraclass correlation coefficient was used to assess the agreement between measurements, A close correlation was found (intraclass correlation coefficient = 0.96), Our results show that time domain ultrasonography seems to be a valid technique for imaging fetal vessels and for measuring blood how velocity. (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:9 / 13
页数:5
相关论文
共 18 条
[1]   The role of transvaginal ultrasonography combined with color velocity imaging and pulsed Doppler in the diagnosis of endometrioma [J].
Alcazar, JL ;
Laparte, C ;
Jurado, M ;
LopezGarcia, G .
FERTILITY AND STERILITY, 1997, 67 (03) :487-491
[2]   Corpus luteum blood flow in abnormal early pregnancy [J].
Alcazar, JL ;
Laparte, C ;
LopezGarcia, G .
JOURNAL OF ULTRASOUND IN MEDICINE, 1996, 15 (09) :645-649
[3]   Measurement error and correlation coefficients [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 313 (7048) :41-42
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   TIME DOMAIN FORMULATION OF PULSE-DOPPLER ULTRASOUND AND BLOOD VELOCITY ESTIMATION BY CROSS-CORRELATION [J].
BONNEFOUS, O ;
PESQUE, P .
ULTRASONIC IMAGING, 1986, 8 (02) :73-85
[6]  
BURNS PN, 1993, ULTRASOUND OBST GYN, P33
[7]  
Eicke B M, 1993, J Neuroimaging, V3, P89
[8]   VOLUME FLOW ESTIMATION USING TIME-DOMAIN CORRELATION AND ULTRASONIC FLOWMETRY [J].
FORSBERG, F ;
LIU, JB ;
RUSSELL, KM ;
GUTHRIE, SL ;
GOLDBERG, BB .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (08) :1037-1045
[9]  
Harrington K, 1996, J ULTRAS MED, V15, P715
[10]  
Hendrikx A., 1996, EUR J ULTRASOUND, V3, P15