Three-dimensional coronary MR angiography performed with subject-specific cardiac acquisition windows and motion-adapted respiratory gating

被引:53
作者
Plein, S
Jones, TR
Ridgway, JP
Sivananthan, MU
机构
[1] Leeds Gen Hosp, British Heart Fdn, Cardiac MRI Unit, Leeds LS1 3EX, W Yorkshire, England
[2] Leeds Gen Hosp, Dept Phys Med, Leeds LS1 3EX, W Yorkshire, England
关键词
D O I
10.2214/ajr.180.2.1800505
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. In coronary MR angiography, data are conventionally accepted in only short and fixed periods of the cardiac and respiratory cycles. We hypothesized that a more flexible and subject-specific approach to cardiac and respiratory gating may shorten scanning times while maintaining image quality. SUBJECTS AND METHODS. We implemented an acquisition technique that uses subject-specific acquisition windows in the cardiac cycle and a motion-adapted gating window for respiratory navigator gating. Cardiac acquisition windows and trigger delays were determined individually from a coronary motion scan. Motion-adapted gating used a 2-mm acceptance window for the central 35% of k-space and a 6-mm window for the outer 65% of k-space. In 10 subjects, three-dimensional coronary MR angiograms of the right and left coronary systems were acquired with this technique (the "adaptive technique") as well as a conventional acquisition method, and the scanning times and image quality were compared. The adaptive technique was then applied prospectively to 40 patients who underwent coronary radiographic angiography. RESULTS. Scanning times with the adaptive technique were reduced by a factor of 2.3 for the right coronary artery and by a factor of 2.2 for the left coronary artery system compared with the conventional technique, mainly because we were able to use longer subject-specific acquisition windows in patients with low heart rates. Subjective and objective measurements of image quality showed no significant differences between the two techniques. Prospective evaluation of MR angiograms, yielded a sensitivity and specificity of 74.3% and 88.2%, respectively, to detect significant coronary artery stenoses. CONCLUSION. Coronary MR angiography with subject-specific acquisition windows and motion-adapted respiratory gating reduces scanning times while maintaining image quality and provides high diagnostic accuracy for the detection of coronary artery stenosis.
引用
收藏
页码:505 / 512
页数:8
相关论文
共 25 条
[1]   Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA [J].
Botnar, RM ;
Stuber, M ;
Danias, PG ;
Kissinger, KV ;
Manning, WJ .
CIRCULATION, 1999, 99 (24) :3139-3148
[2]   Evaluation of free-breathing three-dimensional magnetic resonance coronary angiography with hybrid ordered phase encoding (HOPE) for the detection of proximal coronary artery stenosis [J].
Bunce, MH ;
Jhooti, P ;
Keegan, J ;
Rahman, SL ;
Bunce, C ;
Firmin, DN ;
Davies, SW ;
Lorenz, CH ;
Pennell, DJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (06) :677-684
[3]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[4]  
Chia JM, 2000, J MAGN RESON IMAGING, V12, P678, DOI 10.1002/1522-2586(200011)12:5<678::AID-JMRI4>3.0.CO
[5]  
2-5
[6]   Navigator assessment of breath-hold duration: Impact of supplemental oxygen and hyperventilation [J].
Danias, PG ;
Stuber, M ;
Botnar, RM ;
Kissinger, KV ;
Chuang, ML ;
Manning, WJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) :395-397
[7]   Prospective navigator correction of image position for coronary MR angiography [J].
Danias, PG ;
McConnell, MV ;
Khasgiwala, VC ;
Chuang, ML ;
Edelman, RR ;
Manning, WJ .
RADIOLOGY, 1997, 203 (03) :733-736
[8]   CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
BURSTEIN, D ;
PAULIN, S .
RADIOLOGY, 1991, 181 (03) :641-643
[9]   Quantification of in-plane motion of the coronary arteries during the cardiac cycle: Implications for acquisition window duration for MR flow quantification [J].
Hofman, MBM ;
Wickline, SA ;
Lorenz, CH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03) :568-576
[10]   Hybrid ordered phase encoding (HOPE): An improved approach for respiratory artifact reduction [J].
Jhooti, P ;
Wiesmann, F ;
Taylor, AM ;
Gatehouse, PD ;
Yang, GZ ;
Keegan, J ;
Pennell, DJ ;
Firmin, DN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04) :968-980