Multiplexed liquid arrays for simultaneous detection of simulants of biological warfare agents

被引:130
作者
McBride, MT
Gammon, S
Pitesky, M
O'Brien, TW
Smith, T
Aldrich, J
Langlois, RG
Colston, B
Venkateswaran, KS
机构
[1] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[2] Tetracore Inc, Gaithersburg, MD 20878 USA
关键词
D O I
10.1021/ac026379k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Liquid array-based multiplexed immunoassays designed for rapid, sensitive, specific, and simultaneous detection of multiple simulants of biological warfare agents have been developed. In both blind and standard laboratory trials, we demonstrate the simultaneous detection of four simulant agents from a single sample. The challenge agents comprise broad classes of pathogens (virus, protein toxins, bacterial spores, vegetative cells). Assay performance of each analyte was optimized, and dose-response curves and the limits of detection (LODs) for individual analytes are presented. Assay performance, including dynamic range, sensitivity, and LODs for liquid arrays and enzyme-linked immunosorbant assay were compared and are shown to be similar. Maximum assay sensitivity is obtained in similar to1 h, and good sensitivity is achieved in as little as 30 min. Although the sample matrixes are very complex, even for highly multiplexed assays the samples do not exhibit evidence of nonspecific binding, demonstrating that the assays also have high specificity.
引用
收藏
页码:1924 / 1930
页数:7
相关论文
共 25 条
[1]   Multi-analyte interrogation using the fiber optic biosensor [J].
Anderson, GP ;
King, KD ;
Gaffney, KL ;
Johnson, LH .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11) :771-777
[2]   A fiber optic biosensor for multianalyte detection: importance of preventing fluorophore aggregation [J].
Bakaltcheva, IB ;
Shriver-Lake, LC ;
Ligler, FS .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) :46-51
[3]  
Belgrader P, 1998, CLIN CHEM, V44, P2191
[4]   Surface plasmon resonance multisensing [J].
Berger, CEH ;
Beumer, TAM ;
Kooyman, RPH ;
Greve, J .
ANALYTICAL CHEMISTRY, 1998, 70 (04) :703-706
[5]   Antibody arrays for high-throughput screening of antibody-antigen interactions [J].
de Wildt, RMT ;
Mundy, CR ;
Gorick, BD ;
Tomlinson, IM .
NATURE BIOTECHNOLOGY, 2000, 18 (09) :989-994
[6]   Portable multichannel fiber optic biosensor for field detection [J].
Golden, JP ;
Saaski, EW ;
ShriverLake, LC ;
Anderson, GP ;
Ligler, FS .
OPTICAL ENGINEERING, 1997, 36 (04) :1008-1013
[7]   Detecting staphylococcal enterotoxin B using an automated fiber optic biosensor [J].
King, KD ;
Anderson, GP ;
Bullock, KE ;
Regina, MJ ;
Saaski, EW ;
Ligler, FS .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (02) :163-170
[8]   Automated fiber optic biosensor for multiplexed immunoassays [J].
King, KD ;
Vanniere, JM ;
Leblanc, JL ;
Bullock, KE ;
Anderson, GP .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (13) :2845-2850
[9]   Optical flow-cell multichannel immunosensor for the detection of biological warfare agents [J].
Koch, S ;
Wolf, H ;
Danapel, C ;
Feller, KA .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11) :779-784
[10]  
LANGLOIS RG, 2000, P 1 JOINT C POINT DE, P227