Magnetic resonance angiography is an accurate imaging adjunct to duplex ultrasound scan in patient selection for carotid endarterectomy

被引:33
作者
Back, MR
Wilson, JS
Rushing, G
Stordahl, N
Linden, C
Johnson, BL
Bandyk, DF
机构
[1] Univ S Florida, Coll Med, Div Vasc Surg, Tampa, FL 33606 USA
[2] James A Haley Vet Hosp, Neuroradiol Sect, Tampa, FL 33612 USA
关键词
D O I
10.1067/mva.2000.109330
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The purpose of this study was to evaluate the accuracy of magnetic resonance angiography (MRA) for categorizing the severity of carotid disease relative to duplex ultrasound scan and cerebral contrast arteriography (CA) to determine if MRA imaging could replace the need for cerebral angiography in cases of indeterminate or inadequate duplex scan imaging. Methods: Seventy-four carotid bifurcations in 40 patients undergoing 45 carotid endarterectomies from 1996 to 1998 were imaged with duplex ultrasound scan; MRA (two-dimensional neck and three-dimensional intracranial, time-of-flight technique); and biplanar, digital subtraction cerebral arteriography. Studies were blindly reviewed by one reader who used established threshold velocity criteria for the duplex scan and the North American Symptomatic Carotid Endarterectomy Trial method for MRA and CA to determine the percentage of diameter reduction of the internal carotid artery (ICA). Disease severity was grouped into four categories (< 50%, 50%-74%, 75%-99% stenosis and occlusion), and the results of MRA and duplex ultrasound scan were compared with CA. Results: Sensitivity, specificity, positive predictive value, and negative predictive value for detection of > 50% ICA stenosis were 100%, 96%, 98%, and 100% for MRA and 100%, 72%, 88%, and 100% for duplex ultrasound scan, respectively; similarly, for detection of > 75% ICA stenosis values were 100%, 77%, 76%, and 100% for MRA and 90%, 74%, 72%, and 91% for duplex ultrasound scan, respectively. Both MRA and duplex ultrasound scan accurately differentiated all cases of > 95% stenosis (n = 7) from occlusion (n = 4). Short length ICA flow gaps were present on MRA in all cases of 75% to 99% stenosis and one half of cases of CA-defined 50% to 74% stenosis. In patients with 50% to 74% stenosis, the mean angiographic stenosis was significantly greater when a flow gap was present on MRA (64% +/- 6%) versus no flow gap (57% +/- 7%) (P = .04). There was overall agreement among duplex ultrasound scan, MRA, and CA in 73% of carotids imaged. Of the 24% discordant results between MRA and duplex ultrasound scan, MRA correctly predicted disease severity in all cases, and inaccurate duplex ultrasound scan results were due to overestimation in 83% of cases. The operative plan was altered by CA findings in only one patient (2%) after duplex ultrasound scan and MRA. Conclusions: MRA can accurately categorize the severity of carotid occlusive disease. Duplex ultrasound scan facilitates patient selection for carotid endarterectomy in most cases, but adjunct use of MRA improves diagnostic accuracy for > 75% stenoses and may obviate the need for cerebral arteriography when duplex scan results are inconclusive or demonstrate borderline disease severity.
引用
收藏
页码:429 / 438
页数:10
相关论文
共 21 条
[1]   THE VALUE OF AORTIC-ARCH STUDY IN THE EVALUATION OF CEREBROVASCULAR INSUFFICIENCY [J].
AKERS, DL ;
MARKOWITZ, IA ;
KERSTEIN, MD .
AMERICAN JOURNAL OF SURGERY, 1987, 154 (02) :230-232
[2]   Improving the cost-effectiveness of carotid endarterectomy [J].
Back, MR ;
Harward, TRS ;
Huber, TS ;
Carlton, LM ;
Flynn, TC ;
Seeger, JM .
JOURNAL OF VASCULAR SURGERY, 1997, 26 (03) :456-462
[3]  
BARNETT HJ, 1998, 23 INT JOINT C STROK
[4]   THE UNCERTAINTIES SURROUNDING CAROTID ENDARTERECTOMY [J].
BARNETT, HJM ;
BARNES, RW ;
ROBERTSON, JT .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 268 (21) :3120-3121
[5]   THE ROLE OF DUPLEX SCANNING AND ARTERIOGRAPHY BEFORE CAROTID ENDARTERECTOMY - A PROSPECTIVE-STUDY [J].
DAWSON, DL ;
ZIERLER, RE ;
STRANDNESS, DE ;
CLOWES, AW ;
KOHLER, TR .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (04) :673-683
[6]  
Golledge J, 1996, BRIT J SURG, V83, P1234
[7]   CAROTID-ARTERY - PROSPECTIVE BLINDED COMPARISON OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY WITH CONVENTIONAL ANGIOGRAPHY AND DUPLEX US [J].
HUSTON, J ;
LEWIS, BD ;
WIEBERS, DO ;
MEYER, FB ;
RIEDERER, SJ ;
WEAVER, AL .
RADIOLOGY, 1993, 186 (02) :339-344
[8]   Determination of 60% or greater carotid stenosis: A prospective comparison of magnetic resonance angiography and duplex ultrasound with conventional angiography [J].
Jackson, MR ;
Chang, AS ;
Robles, HA ;
Gillespie, DL ;
Olsen, SB ;
Kaiser, WJ ;
Goff, JM ;
O'Donnell, SD ;
Rich, NM .
ANNALS OF VASCULAR SURGERY, 1998, 12 (03) :236-243
[9]   PERIOPERATIVE IMAGING STRATEGIES FOR CAROTID ENDARTERECTOMY - AN ANALYSIS OF MORBIDITY AND COST-EFFECTIVENESS IN SYMPTOMATIC PATIENTS [J].
KENT, KC ;
KUNTZ, KM ;
PATEL, MR ;
KIM, D ;
KLUFAS, RA ;
WHITTEMORE, AD ;
POLAK, JF ;
SKILLMAN, JJ ;
EDELMAN, RR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (11) :888-893
[10]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174