Three-dimensional endocardial impedance mapping: a new approach for myocardial infarction assessment

被引:17
作者
Wolf, T
Gepstein, L
Hayam, G
Zaretzky, A
Shofty, R
Kirshenbaum, D
Uretzky, G
Oron, U
Ben-Haim, SA
机构
[1] Technion Israel Inst Technol, Bruce Rappaport Fac Med, Cardiovasc Syst Lab, IL-31096 Haifa, Israel
[2] Technion Israel Inst Technol, Carmel Med Ctr, Dept Cardiothorac Surg, IL-31096 Haifa, Israel
[3] Tel Aviv Univ, Dept Zool, IL-69978 Tel Aviv, Israel
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2001年 / 280卷 / 01期
关键词
myocardial viability assessment; electromechanical coupling; electrophysiology;
D O I
10.1152/ajpheart.2001.280.1.H179
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Precise identification of infarcted myocardial tissue is of importance in diagnostic and interventional cardiology. A three-dimensional, catheter-based endocardial electromechanical mapping technique was used to assess the ability of local endocardial impedance in delineating the exact location, size, and border of canine myocardial infarction. Electromechanical mapping of the left ventricle was performed in a control group (n = 10) and 4 wk after left anterior descending coronary artery ligation (n = 10). Impedance, bipolar electrogram amplitude, and endocardial local shortening (LS) were quantified. The infarcted area was compared with the corresponding regions in controls, revealing a significant reduction in impedance values [infarcted vs. controls: 168.8 +/- 11.7 and 240.7 +/- 22.3 Omega, respectively (means +/- SE), P< 0.05] bipolar electrogram amplitude (1.8 +/- 0.2 mV, 4.4 +/- 0.7 mV, P< 0.05), and LS (-2.36 +/- 1.6%, 11.9 +/- 0.9%, P< 0.05). The accuracy of the impedance maps in delineating the location and extent of the infarcted region was demonstrated by the high correlation with the infarct area (Pearson's correlation coefficient = 0.942) and the accurate identification of the infarct borders in pathology. By accurately defining myocardial infarction and its borders, endocardial impedance mapping may become a clinically useful tool in differentiating healthy from necrotic myocardial tissue.
引用
收藏
页码:H179 / H188
页数:10
相关论文
共 32 条
[21]   IDENTIFICATION AND DIFFERENTIATION OF RESTING MYOCARDIAL ISCHEMIA AND INFARCTION IN MAN WITH POSITRON COMPUTED-TOMOGRAPHY, F-18-LABELED FLUORODEOXYGLUCOSE AND N-13 AMMONIA [J].
MARSHALL, RC ;
TILLISCH, JH ;
PHELPS, ME ;
HUANG, SC ;
CARSON, R ;
HENZE, E ;
SCHELBERT, HR .
CIRCULATION, 1983, 67 (04) :766-778
[22]  
Masson P., 1929, J TECH METHODS, V12, P75
[23]  
PERONEFILIARDI P, 1996, CIRCULATION, V94, P2712
[24]   Noninvasive measurements of infarct size after thrombolysis with a necrosis-avid MRI contrast agent [J].
Pislaru, SV ;
Ni, YC ;
Pislaru, C ;
Bosmans, H ;
Miao, Y ;
Bogaert, J ;
Dymarkowski, S ;
Semmler, W ;
Marchal, G ;
Van de Werf, FJH .
CIRCULATION, 1999, 99 (05) :690-696
[25]   RESISTIVITY OF BODY TISSUES AT LOW FREQUENCIES [J].
RUSH, S ;
MCFEE, R ;
ABILDSKOV, JA .
CIRCULATION RESEARCH, 1963, 12 (01) :40-&
[26]  
Sasaki E, 1994, ASAIO J, V40, pM826, DOI 10.1097/00002480-199407000-00113
[27]   INSIGHTS INTO CORONARY-ARTERY DISEASE GAINED FROM METABOLIC IMAGING [J].
SCHELBERT, HR ;
BUXTON, D .
CIRCULATION, 1988, 78 (03) :496-505
[28]   SPECIFIC RESISTANCE OF BODY TISSUES [J].
SCHWAN, HP ;
KAY, CF .
CIRCULATION RESEARCH, 1956, 4 (06) :664-670
[29]  
SCHWARTZMAN D, 1994, J AM COLL CARDIOL, pA202
[30]   RELATION BETWEEN IMPEDANCE AND ENDOCARDIAL CONTACT DURING RADIOFREQUENCY CATHETER ABLATION [J].
STRICKBERGER, SA ;
VORPERIAN, VR ;
MAN, KC ;
WILLIAMSON, BD ;
KALBFLEISCH, SJ ;
HASSE, C ;
MORADY, F ;
LANGBERG, JJ .
AMERICAN HEART JOURNAL, 1994, 128 (02) :226-229