Micellar extraction and high performance liquid chromatography-ultra violet determination of some explosives in water samples

被引:88
作者
Babaee, Saeed [1 ]
Beiraghi, Asadollah [2 ]
机构
[1] Malek Ashtar Univ Technol, Fac Mat, Tehran, Iran
[2] Tarbiat Moallem Univ, Fac Chem, Tehran, Iran
关键词
Cloud point extraction; Explosives; High performance liquid chromatography; Surfactants; CLOUD-POINT EXTRACTION; SOLID-PHASE MICROEXTRACTION; ELECTRON-CAPTURE DETECTION; OUT SOLVENT-EXTRACTION; GAS-CHROMATOGRAPHY; CAPILLARY-ELECTROPHORESIS; NITRAMINE EXPLOSIVES; ELECTROCHEMICAL DETECTION; NITROAROMATIC EXPLOSIVES; AMPEROMETRIC DETECTION;
D O I
10.1016/j.aca.2009.12.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method based on the cloud point extraction combined with high performance liquid chromatography is used for the extraction, separation and determination of four explosives; octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazine (HMX), hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), 2,4,6-trinitrotoluene (TNT) and pentaerythritol tetranitrate (PETN). These compounds are extracted by using of Triton X-114 and cetyl-trimethyl ammonium bromide (CTAB). After extraction, the samples were analyzed using a HPLC-UV system. The parameters affecting extraction efficiency (such as Triton X-I 14 and CTAB concentrations, amount of Na2SO4, temperature, incubation and centrifuge times) were evaluated and optimized. Under the optimum conditions, the preconcentration factor was 40 and the improvement factors of 34, 29, 61 and 42 with detection limits of 0.09, 0.14, 0.08 and 0.40 (mu g L-1) were obtained for HMX, RDX, TNT and PETN, respectively. The proposed method was successfully applied to the determination of these Compounds in water samples and showed recovery percentages of 97-102% with RSD values of 2.13-4.92%. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:9 / 13
页数:5
相关论文
共 43 条
[1]  
AKHAVAN J, 1980, EXPLOSIVES PROPELLAN, V12
[2]  
[Anonymous], 1999, Forensic and environmental detection of explosives
[3]   Analysis of nitroaromatic compounds in urine by gas chromatography mass spectrometry for the biological monitoring of explosives [J].
Bader, M ;
Göen, T ;
Müller, J ;
Angerer, J .
JOURNAL OF CHROMATOGRAPHY B, 1998, 710 (1-2) :91-99
[4]   Cloud-point formation based on mixed micelles for the extraction, preconcentration and spectrophotometric determination of trace amounts of beryllium in water samples [J].
Beiraghi, Asadollah ;
Zarei, Ali Reza ;
Babaee, Saeed .
ANALYTICAL SCIENCES, 2007, 23 (05) :527-531
[5]   Separation and preconcentration of ultra trace amounts of beryllium in water samples using mixed micelle-mediated extraction and determination by inductively coupled plasma-atomic emission spectrometry [J].
Beiraghi, Assadollah ;
Babaee, Saeed .
ANALYTICA CHIMICA ACTA, 2008, 607 (02) :183-190
[6]   Use of reversed-phase high-performance liquid chromatography-diode array detection for complete separation of 2,4,6-trinitrotoluene metabolites and EPA method 8330 explosives: influence of temperature and an ion-pair reagent [J].
Borch, T ;
Gerlach, R .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1022 (1-2) :83-94
[7]   Analytical applications of organized assemblies for on-line spectrometric determinations: present and future [J].
Burguera, JL ;
Burguera, M .
TALANTA, 2004, 64 (05) :1099-1108
[8]   Surfactant cloud point extraction and preconcentration of organic compounds prior to chromatography and capillary electrophoresis [J].
Carabias-Martínez, R ;
Rodríguez-Gonzalo, E ;
Moreno-Cordero, B ;
Pérez-Pavón, JL ;
García-Pinto, C ;
Laespada, EF .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (01) :251-265
[9]   Sensitive determination of RDX, nitroso-RDX metabolites, and other munitions in ground water by solid-phase extraction and isotope dilution liquid chromatography-atmospheric pressure chemical ionization mass spectrometry [J].
Cassada, DA ;
Monson, SJ ;
Snow, DD ;
Spalding, RF .
JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) :87-95
[10]   Trace humic and fulvic acid determination in natural water by cloud point extraction/preconcentration using non-ionic and cationic surfactants with FI-UV detection [J].
de Wuilloud, JCA ;
Wuilloud, RG ;
Sadi, BBM ;
Caruso, JA .
ANALYST, 2003, 128 (05) :453-458