Comparison of 3-D maximum a posteriori and filtered backprojection algorithms for high-resolution animal imaging with microPET

被引:103
作者
Chatziioannou, A [1 ]
Qi, J
Moore, A
Annala, A
Nguyen, K
Leahy, R
Cherry, SR
机构
[1] Univ Calif Los Angeles, Sch Med, Dept Mol & Med Pharmacol, Crump Inst Biol Imaging, Los Angeles, CA 90095 USA
[2] Univ Calif Berkeley, Ctr Funct Imaging, Berkeley, CA 94720 USA
[3] Univ So Calif, Inst Signal & Image Proc, Los Angeles, CA 90089 USA
关键词
image reconstruction; positron emission tomography; small animal imaging;
D O I
10.1109/42.870260
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We have evaluated the performance of two three-dimensional (3-D) reconstruction algorithms with data acquired from microPET, a high resolution tomograph dedicated to small animal imaging. The first was a linear filtered-backprojection algorithm (FBP) with reprojection of the missing data, and the second was a statistical maximum a posteriori probability algorithm (MAP), The two algorithms were evaluated in terms of their resolution performance, both in phantoms and in vivo. Sixty independent realizations of a phantom simulating the brain of a baby monkey were acquired, each containing three million counts. Each of these realizations was reconstructed independently with both algorithms. The ensemble of the 60 reconstructed realizations was used to estimate the standard deviation as a measure of the noise for each reconstruction algorithm, More detail was recovered in the MAP reconstruction without an increase in noise relative to FBP. Studies in a simple cylindrical compartment phantom demonstrated improved recovery of known activity ratios with MAP. Finally, in vivo studies also demonstrated a clear improvement in spatial resolution using the MAP algorithm. The quantitative accuracy of the MAP reconstruction was also evaluated by comparison with autoradiography and direct well counting of tissue samples and was shown to be superior.
引用
收藏
页码:507 / 512
页数:6
相关论文
共 18 条
[11]  
OLLINGER JM, 1996, 1996 IEEE NUCL SCI S, V3, P1594
[12]  
QI J, IN PRESS IEEE T MED
[13]   High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner [J].
Qi, JY ;
Leahy, RM ;
Cherry, SR ;
Chatziioannou, A ;
Farquhar, TH .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) :1001-1013
[14]   A theoretical study of the contrast recovery and variance of MAP reconstructions from PET data [J].
Qi, JY ;
Leahy, RM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (04) :293-305
[15]  
Riddell C, 1998, J NUCL MED, V39, p80P
[16]   IMPLEMENTATION AND EVALUATION OF A CALCULATED ATTENUATION CORRECTION FOR PET [J].
SIEGEL, S ;
DAHLBOM, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :1117-1121
[17]  
TERSTEGGE A, 1996, 1996 IEEE NUCL SCI S, V3, P1603
[18]  
YAVUZ M, 1996, P IEEE NUCL SCI S ME, V2, P1067