Advances in biosensors for detection of pathogens in food and water

被引:376
作者
Leonard, P
Hearty, S
Brennan, J
Dunne, L
Quinn, J
Chakraborty, T
O'Kennedy, R [1 ]
机构
[1] Dublin City Univ, Sch Biotechnol, Dublin 9, Ireland
[2] Dublin City Univ, Natl Ctr Sensor Res, Dublin 9, Ireland
[3] Texas Instruments Inc, Austin, TX USA
[4] Univ Giessen, Inst Med Microbiol, D-35392 Giessen, Germany
关键词
biosensor; surface plasmon resonance (SPR); piezoelectric; amperometric; potentiometric;
D O I
10.1016/S0141-0229(02)00232-6
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
While most microbes play an important role in nature, certain potentially harmful microbes can contaminate food and water, and cause a plethora of infectious diseases in both animals and humans. Conventional methods for detecting microbial contamination have primarily relied on time-consuming enrichment steps, followed by biochemical identification, having a total assay time of up to I week in certain cases. Over the last decade, a great deal of research has focused on the development of biological sensors for the detection of micro-organisms, allowing rapid and "real-time" identification. This paper reviews some of the most commonly used biosensor systems based on their transducer properties, which include surface plasmon resonance (SPR), amperometric, potentiometric, and acoustic wave sensors and their applications for the detection of pathogens in food and water. It also highlights some of the limitations of applying biosensors for the detection of pathogens, such as sensitivity, cost and the need for sample pre-treatment. (C) 2002 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:3 / 13
页数:11
相关论文
共 73 条
  • [1] Highly sensitive flow-injection immunoassay system for rapid detection of bacteria
    Abdel-Hamid, I
    Ivnitski, D
    Atanasov, P
    Wilkins, E
    [J]. ANALYTICA CHIMICA ACTA, 1999, 399 (1-2) : 99 - 108
  • [2] Flow-through immunofiltration assay system for rapid detection of E-coli O157:H7
    Abdel-Hamid, I
    Ivnitski, D
    Atanasov, P
    Wilkins, E
    [J]. BIOSENSORS & BIOELECTRONICS, 1999, 14 (03) : 309 - 316
  • [3] Artault S., 2001, International Food Hygiene, V12, P23
  • [4] Evaluation of antibody immobilization methods for piezoelectric biosensor application
    Babacan, S
    Pivarnik, P
    Letcher, S
    Rand, AG
    [J]. BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) : 615 - 621
  • [5] Recombinant single chain antibodies in bioelectrochemical sensors
    Benhar, I
    Eshkenazi, I
    Neufeld, T
    Opatowsky, J
    Shaky, S
    Rishpon, J
    [J]. TALANTA, 2001, 55 (05) : 899 - 907
  • [6] Filtration capture and immunoelectrochemical detection for rapid assay of Escherichia coli O157:H7
    Brewster, JD
    Mazenko, RS
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1998, 211 (1-2) : 1 - 8
  • [7] BSAT N, 1994, FOOD TECHNOL-CHICAGO, V48, P142
  • [8] Piezoelectric quartz crystal biosensors
    Bunde, RL
    Jarvi, EJ
    Rosentreter, JJ
    [J]. TALANTA, 1998, 46 (06) : 1223 - 1236
  • [9] CAHILL D, 1995, ENCY ANAL SCI, V4, P2057
  • [10] CATER RM, 1995, J IMMUNOL METHODS, V187, P121