Right Y-graft, a new surgical technique using mammary arteries for total myocardial revascularization

被引:25
作者
Bonacchi, M
Prifti, E
Giunti, G
Salica, A
机构
[1] Univ Rome La Sapienza, Div 2, Ist Chirurg Cuore Grossi Vasi, Rome, Italy
[2] Osped Maggiore Carita, Ist Chirurg Cardiovasc, Novara, Italy
关键词
D O I
10.1016/S0003-4975(00)01500-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We report a new technique that consists of a right Y-graft using only skeletonized internal mammary arteries (IMA) for total arterial myocardial revascularization. Methods. This technique consists of anastomosing the in situ left IMA (LIMA) and right IMA (RIMA) to the left anterior descending and obtuse marginal artery, via the transverse sinus, respectively. The distal free LIMA was anastomosed to the right coronary artery and afterwards in a Y fashion to the RIMA stem. Eleven patients with triple-vessel disease underwent coronary artery bypass grafting using this technique. Postoperatively and at follow-up all patients underwent color Doppler contrast-enhanced transthoracic echocardiography (TTE) before and after an adenosine provocation test. Results. Overall, 33 IMA-coronary anastomoses were made and II right Y-grafts were constructed. At 1 week after operation color Doppler contrast-enhanced TTE before and after the adenosine provocation test, respectively, showed an increase in LIMA stem diameter of 0.31 mm and in mean flow 62 mL/min. Coronary now reserve (CFR) was 2 +/- 0.3. The increase in RIMA stem diameter was 0.2 mm and in mean flow was 121.7 mL/min. Coronary flow reserve was 2.5 +/- 0.4. Only 1 patient demonstrated an anomalous Doppler pattern, suggesting a partial Y-graft closure. Conclusions. Such a technique permits total myocardial revascularization using only mammary arteries and left ventricular perfusion from both IMAs simultaneously. The color Doppler contrast-enhanced TTE is a rapid, accurate, and noninvasive test allowing a good assessment of IMA patency. (Ann Thorac Surg 2000;70:820-3) (C) 2000 by The Society of Thoracic Surgeons.
引用
收藏
页码:820 / 823
页数:4
相关论文
共 21 条
[1]   FLOW CAPACITY OF INTERNAL MAMMARY ARTERY GRAFTS - EARLY RESTRICTION AND LATER IMPROVEMENT ASSESSED BY DOPPLER GUIDE-WIRE - COMPARISON WITH SAPHENOUS-VEIN GRAFTS [J].
AKASAKA, T ;
YOSHIKAWA, J ;
YOSHIDA, K ;
MAEDA, K ;
HOZUMI, T ;
NASU, M ;
SHOMURA, T .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (03) :640-647
[2]  
BROWN AH, 1991, J THORAC CARDIOV SUR, V102, P753
[3]  
Butany JW, 1998, CAN J CARDIOL, V14, P671
[4]   New noninvasive method for coronary flow reserve assessment - Contrast-enhanced transthoracic second harmonic echo Doppler [J].
Caiati, C ;
Montaldo, C ;
Zedda, N ;
Bina, A ;
Iliceto, S .
CIRCULATION, 1999, 99 (06) :771-778
[5]   Bilateral internal mammary artery grafting: Midterm results of pedicled versus skeletonized conduits [J].
Calafiore, AM ;
Vitolla, G ;
Iaco, AL ;
Fino, C ;
Di Giammarco, G ;
Marchesani, F ;
Teodori, G ;
D'Addario, G ;
Mazzei, V .
ANNALS OF THORACIC SURGERY, 1999, 67 (06) :1637-1642
[6]   COMPOSITE ARTERIAL CONDUITS FOR A WIDER ARTERIAL MYOCARDIAL REVASCULARIZATION [J].
CALAFIORE, AM ;
DIGIAMMARCO, G ;
LUCIANI, N ;
MADDESTRA, N ;
DINARDO, E ;
ANGELINI, R .
ANNALS OF THORACIC SURGERY, 1994, 58 (01) :185-190
[7]  
Green G E, 1968, Ann Thorac Surg, V5, P443
[8]   INFLUENCE OF THE INTERNAL-MAMMARY-ARTERY GRAFT ON 10-YEAR SURVIVAL AND OTHER CARDIAC EVENTS [J].
LOOP, FD ;
LYTLE, BW ;
COSGROVE, DM ;
STEWART, RW ;
GOORMASTIC, M ;
WILLIAMS, GW ;
GOLDING, LAR ;
GILL, CC ;
TAYLOR, PC ;
SHELDON, WC ;
PROUDFIT, WL .
NEW ENGLAND JOURNAL OF MEDICINE, 1986, 314 (01) :1-6
[9]  
LYTLE BW, 1998, AATS M BOST MASS MAY
[10]   ATHEROSCLEROSIS IN AORTOCORONARY BYPASS GRAFTS - MORPHOLOGICAL-STUDY AND RISK FACTOR-ANALYSIS 6 TO 12 YEARS AFTER SURGERY [J].
NEITZEL, GF ;
BARBORIAK, JJ ;
PINTAR, K ;
QURESHI, I .
ARTERIOSCLEROSIS, 1986, 6 (06) :594-600