A sequential injection method for the determination of aluminum in drinking water using fluorescence enhancement of the aluminum-morin complex in micellar media

被引:54
作者
Al-Kindy, SMZ [1 ]
Suliman, FO [1 ]
Salama, SB [1 ]
机构
[1] Sultan Qaboos Univ, Coll Sci, Dept Chem, Al Khoud 123, Oman
关键词
aluminum; morin; fluorescence; Tween-20; water analysis;
D O I
10.1016/S0026-265X(03)00025-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A robust and simple sequential injection (SI) method for the assay of aluminum ions in natural water is described. The method is based on the enhancement of the fluorescence of the aluminium-morin complex in the presence of a non-ionic surfactant (Tween-20). The fluorescence of the complex is monitored at an emission wavelength of 495 nm with excitation at 425 nm. The pH, morin concentration and the aspirated sample volume were optimized simultaneously using a chemometric method. The optimum operating conditions are: 150 mul aspirated sample volume, 20 muM morin concentration, a pH of 4.5 and 0.8% Tween-20. Using these optimum conditions a linear calibration curve was obtained from 50 to 1000 ppb. The detection limit was 3 ppb and the maximum relative standard deviation (n=5) of the method was 2.9%. The method was successfully applied for the determination of aluminum ions in natural water samples. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:173 / 179
页数:7
相关论文
共 17 条
[1]  
[Anonymous], 1999, ENV CHEM
[2]   NOVEL SINGLE STANDARD CALIBRATION AND DILUTION METHOD PERFORMED BY THE SEQUENTIAL INJECTION TECHNIQUE [J].
BARON, A ;
GUZMAN, M ;
RUZICKA, J ;
CHRISTIAN, GD .
ANALYST, 1992, 117 (12) :1839-1844
[3]  
CAMPANA AM, 2001, ANAL CHIM ACTA, V447, P219
[4]   Electrochemical detection of aluminium using single-use sensors [J].
Dilleen, JW ;
Birch, BJ ;
Haggett, BGD .
ANALYTICAL COMMUNICATIONS, 1999, 36 (11-12) :363-365
[5]   INCREASE IN THE SENSITIVITY OF THE FLUORESCENT REACTION OF THE COMPLEXING OF ALUMINUM WITH MORIN USING SURFACTANT AGENTS [J].
ESCRICHE, JM ;
CIRUGEDA, MD ;
HERNANDEZ, FH .
ANALYST, 1983, 108 (1292) :1386-1391
[6]   Time resolved fluorescence spectroscopy of quercetin and morin complexes with Al3+ [J].
Gutierrez, AC ;
Gehlen, MH .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2002, 58 (01) :83-89
[7]  
HEMNILA I, 1985, ANAL CHEM, V57, P1676
[8]   Determination of aluminum in beverages by automated non-segmented continuous flow analysis with fluorescent detection of the lumogallion complex [J].
Hoch, RL .
ANALYST, 1999, 124 (05) :793-796
[9]  
KONONENKO LI, 1975, UKR KHIM ZH+, V41, P1098
[10]  
MEDEL AS, 1987, ANALYST, V112, P493