Comparative diagnostic performance of TACT® slices and its multiple source images:: an in vitro study

被引:7
作者
Abreu, M [1 ]
Yi-Ching, L [1 ]
Abreu, A [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Stomatol, Sch Dent, BR-88034000 Florianopolis, SC, Brazil
关键词
TACT; direct digital images; caries detection; ROC; comparative study;
D O I
10.1259/dmfr/28470759
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare the diagnostic performances provided by tuned aperture computed tomography (TACT(R)) slices and the multiple images that they originate from in the detection of primary caries on the proximal surfaces of posterior teeth. Study design: Eight direct digital radiography images of each of 40 posterior teeth were acquired with a digital sensor. These source images were used to generate TACT(R) slices of the teeth. Eight trained observers were calibrated in the use of both TACT(R) slices and the eight source images of each tooth. They were asked to assess the presence/absence of proximal caries in the teeth using a 5-point rating scale. Observers' assessments were compared with the ground truth provided by histological examination of tooth sections. Areas under the receiver operating characteristic (ROC) curves (A(z)) were calculated for each combination of observer and image modality. Analysis of variance (ANOVA) was used to test the ROC values for potential statistical differences. Results: Mean ROC A(z) values were 0.760 for TACT(R) slices and 0.771 for its multiple source images for the detection of primary proximal caries. ANOVA showed no statistically significant differences either between modalities (P = 0.656) or between observers (P = 0.851). Conclusion: TACT(R) slices and its multiple source images provide comparable diagnostic performance for proximal caries detection.
引用
收藏
页码:93 / 97
页数:5
相关论文
共 26 条
[11]  
Mjor I A, 1997, Quintessence Int, V28, P99
[12]   Tuned aperture computed tomography and detection of recurrent caries [J].
Nair, MK ;
Tyndall, DA ;
Ludlow, JB ;
May, K .
CARIES RESEARCH, 1998, 32 (01) :23-30
[13]   Accuracy of tuned aperture computed tomography in the diagnosis of radicular fractures in non-restored maxillary anterior teeth -: an in vitro study [J].
Nair, MK ;
Nair, UP ;
Gröndahl, HG ;
Webber, RL .
DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (05) :299-304
[14]   Tuned aperture computed tomography to evaluate osseous healing [J].
Nair, MK ;
Seyedain, A ;
Agarwal, S ;
Webber, RL ;
Nair, UP ;
Piesco, NP ;
Mooney, MP ;
Grondahl, HG .
JOURNAL OF DENTAL RESEARCH, 2001, 80 (07) :1621-1624
[15]   Comparative evaluation of Tuned Aperture Computed Tomography® for the detection of mandibular fractures [J].
Nair, MK ;
Webber, RL ;
Johnson, MP .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (05) :297-301
[16]   Identification of root canals in molars by tuned-aperture computed tomography [J].
Nance, R ;
Tyndall, D ;
Levin, LG ;
Trope, M .
INTERNATIONAL ENDODONTIC JOURNAL, 2000, 33 (04) :392-396
[17]  
Nance RS, 2000, ENDOD DENT TRAUMATOL, V16, P24
[18]   Evaluation of tuned-aperture computed tomography in the detection of simulated periodontal defects [J].
Ramesh, A ;
Ludlow, JB ;
Webber, RL ;
Tyndall, DA ;
Paquette, D .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2002, 93 (03) :341-349
[19]   Evaluation of tuned aperture computed tomography (TACT®) in the localization of simulated periodontal defects [J].
Ramesh, A ;
Ludlow, JB ;
Webber, RL ;
Tyndall, DA ;
Paquette, D .
DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (06) :319-324
[20]  
Rashedi Behnoush, 2003, J Prosthodont, V12, P176, DOI 10.1016/S1059-941X(03)00004-4