Simultaneous determination of ethylbenzene, indan, indene and acenaphthene in air by capillary gas chromatography

被引:2
作者
Bieniek, G [1 ]
机构
[1] Silesian Med Acad, Dept Biochem & Biophys, PL-41200 Sosnowiec, Poland
关键词
air analysis; environmental analysis; ethylbenzene; indan; indene; acenaphthene;
D O I
10.1016/S0021-9673(00)00657-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An attempt was made to establish a method for the simultaneous determination of ethylbenzene, indan, indene and acenaphthene by capillary gas chromatography with flame ionization detection. The air was sampled on charcoal tubes and extracted with carbon disulfide-methanol (60:1, v/v). The four analytes were separated by gas chromatography using a capillary column of cross-linked 5% phenylmethylsilicone. Under the applied conditions the method showed detection limits of 1.8 mu g/m(3) for ethylbenzene, 2.1 mu g/m(3) for indan, 2.8 mu g/m(3) for indene and 3.4 mu g/m(3) for acenaphthene. Relative standard deviations were as follows: ethylbenzene, 6.2%; indan, 9.9%; indene, 13.6%; and acenaphthene, 14.4%. The recoveries for these compounds were 98.6, 97.9, 55.7 and 52.1%, and the accuracies were 2.5, 3.0, 44.3 and 47.8%, a working range of 1.5-30 ng/mu l for ethylbenzene and 0.75-15 ng/mu l for indan, indene and acenaphthene. The method was found to be suitable for the determination of environmental and occupational analysed ethylbenzene, indan, indene and acenaphthene exposure. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:361 / 365
页数:5
相关论文
共 9 条
[1]  
ACGIH (American Conference of Governmental Industrial Hygienists), 1997, THRESH LIM VAL CHEM
[2]   MODIFIED ANALYTICAL TECHNIQUE FOR THE DETERMINATION OF TRACE ORGANICS IN WATER USING DYNAMIC HEADSPACE AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BIANCHI, A ;
VARNEY, MS ;
PHILLIPS, J .
JOURNAL OF CHROMATOGRAPHY, 1989, 467 (01) :111-128
[3]   Urinary naphthols as an indicator of exposure to naphthalene [J].
Bieniek, G .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1997, 23 (06) :414-420
[4]  
Bieniek G, 1998, AM J IND MED, V34, P445, DOI 10.1002/(SICI)1097-0274(199811)34:5<445::AID-AJIM5>3.0.CO
[5]  
2-P
[6]   Determination of benzene, toluene, ethylbenzene and xylenes in indoor air at environmental levels using diffusive samplers in combination with headspace solid-phase microextraction and high-resolution gas chromatography-flame ionization detection [J].
Elke, K ;
Jermann, E ;
Begerow, J ;
Dunemann, L .
JOURNAL OF CHROMATOGRAPHY A, 1998, 826 (02) :191-200
[7]  
*NIOSH, 1994, MAN AN METH
[8]  
*OSHA, 1993, METH EV GUID
[9]   Determination of benzene and alkylated benzenes in ambient and exhaled air by microwave desorption coupled with chromatography mass spectrometry [J].
Riedel, K ;
Ruppert, T ;
Conze, C ;
Scherer, G ;
Adlkofer, F .
JOURNAL OF CHROMATOGRAPHY A, 1996, 719 (02) :383-389