Advances toward the implantable artificial pancreas for treatment of diabetes

被引:88
作者
Jaremko, J [1 ]
Rorstad, O [1 ]
机构
[1] Univ Calgary, Dept Med, Calgary, AB T2N 4N1, Canada
关键词
D O I
10.2337/diacare.21.3.444
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recent research on development of the implantable artificial pancreas for treatment of diabetes is reviewed, based on a Medline literature search that focused on glucose sensors. insulin pumps, and pump control systems. To achieve a closed feedback loop, a clinically applicable implantable artificial pancreas requires miniaturization and coordination of three components: an insulin pump, a blood glucose monitor, and a control system. Recent clinical studies have demonstrated that implantable insulin pumps are feasible for satisfaction control of diabetes for over a year, with the major complication being obstruction of the infusion catheter. Research on continuous glucose sensors has predominantly used the glucose-oxidase reaction or near-infrared light spectroscopy. Implantable glucose oxidase sensors have been limited by local factors causing unstable signal output, whereas optical sensors must overcome interference by substances with absorption spectra similar to glucose. Investigators have developed control algorithms in an effort to stabilize operation of the integrated artificial pancreas in the face of variations in sensor output and pump function. The ultimate goals of fully automatic glucose control by an artificial pancreas include prevention or delay of chronic complications of diabetes, lowered risk of hypoglycemia, and less patient inconvenience and discomfort than with multiple daily glucose self-tests and insulin injection. The recent developments of optical glucose sensing, radiotelemetry systems to link pump and sensor, and miniaturization and refinement of insulin pumps are significant steps toward a clinically applicable artificial pancreas.
引用
收藏
页码:444 / 450
页数:7
相关论文
共 36 条
  • [1] *AM DIAB ASS, 1997, DIABETES CARE S1, V20, pS50
  • [2] APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS
    ARMOUR, JC
    LUCISANO, JY
    MCKEAN, BD
    GOUGH, DA
    [J]. DIABETES, 1990, 39 (12) : 1519 - 1526
  • [3] Non-invasive glucose monitoring
    Arnold, MA
    [J]. CURRENT OPINION IN BIOTECHNOLOGY, 1996, 7 (01) : 46 - 49
  • [4] FRENCH MULTICENTER EXPERIENCE OF IMPLANTABLE INSULIN PUMPS
    BROUSSOLLE, C
    JEANDIDIER, N
    HANAIREBROUTIN, H
    [J]. LANCET, 1994, 343 (8896) : 514 - 515
  • [5] A SIMULATION STUDY ON A SELF-TUNING PORTABLE CONTROLLER OF BLOOD-GLUCOSE
    BRUNETTI, P
    COBELLI, C
    CRUCIANI, P
    FABIETTI, PG
    FILIPPUCCI, F
    SANTEUSANIO, F
    SARTI, E
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (01) : 51 - 57
  • [6] Simulation and Optimisation of a Self-regulating Insulin Delivery System
    Fischel-Ghodsian, F.
    Newton, J. M.
    [J]. JOURNAL OF DRUG TARGETING, 1993, 1 (01) : 67 - 80
  • [7] DEVELOPMENT OF THE IMPLANTABLE GLUCOSE SENSOR - WHAT ARE THE PROSPECTS AND WHY IS IT TAKING SO LONG
    GOUGH, DA
    ARMOUR, JC
    [J]. DIABETES, 1995, 44 (09) : 1005 - 1009
  • [8] FEASIBILITY OF INTRAPERITONEAL INSULIN THERAPY WITH PROGRAMMABLE IMPLANTABLE PUMPS IN IDDM - A MULTICENTER STUDY
    HANAIREBROUTIN, H
    BROUSSOLLE, C
    JEANDIDIER, N
    RENARD, E
    GUERCI, B
    HAARDT, MJ
    LASSMANNVAGUE, V
    PINGET, M
    TAUBER, JP
    BRINGER, J
    VAGUE, P
    RACCAH, D
    DROUIN, P
    ZIEGLER, O
    SELAM, JL
    SLAMA, G
    GILLY, F
    [J]. DIABETES CARE, 1995, 18 (03) : 388 - 392
  • [9] Hanning C. D., 1995, British Medical Journal, V311, P367
  • [10] IMPLANTABLE INSULIN PUMPS AND METABOLIC CONTROL
    HEPP, KD
    [J]. DIABETOLOGIA, 1994, 37 : S108 - S111