MR arthrography of the shoulder, hip, and wrist: Evaluation of contrast dynamics and image quality with increasing injection-to-imaging time

被引:38
作者
Andreisek, Gustav
Duc, Sylvain R.
Froehlich, Johannes M.
Hodler, Juerg
Weishaupt, Dominik
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Orthoped Univ Hosp BAlgrist, Dept Radiol, Zurich, Switzerland
[3] Guerbet AG, Zurich, Switzerland
关键词
arthrography; hip; MR; musculoskeletal imaging; shoulder; wrist;
D O I
10.2214/AJR.06.0719
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
OBJECTIVE. The purpose of our study was to investigate the contrast dynamics and the relationship between visualization of intraarticular structures and time elapsed between intraarticular injection of contrast agent and MRI in symptomatic patients referred for MR arthrography of the shoulder, hip, and wrist. SUBJECTS AND METHODS. Our local ethics committees and the national drug administration approved this multicentric study. We prospectively studied 11 shoulders, 11 hips, and 10 wrists. After the intraarticular gadolinium injection, patients underwent a baseline MR arthrography protocol (time point [TP] 1) and subsequent MRI at another four time points (TP 2-TP 5) up to 240 minutes. The course of contrast-to-noise ratio (CNR) over time was calculated. Three observers assessed the degree of visualization of different intraarticular structures and the overall image quality at each time point using a 3-point scale and a 5-point scale, respectively. RESULTS. For all joints, CNR measurements showed peak CNR at TP 1 (21 minutes) and TP 2 (45 minutes) with a subsequent, near-logarithmic decline of CNR values over time. Visualization of different anatomic structures decreased over time. Overall image quality was insufficient for diagnostic purposes at TP 3 (96 minutes) in three (27%) of 11 shoulders and in three (27%) of 11 hips. In two (20%) of 10 wrists, image quality was insufficient at TP 2 (45 minutes). CONCLUSION. For MR arthrography, the degree of visualization of intraarticular structures depends on the time elapsed between contrast injection and MRI. MR arthrography of the shoulder and hip should be performed within 90 minutes, and MR arthrography of the wrist should be performed within 45 minutes, after intraarticular injection.
引用
收藏
页码:1081 / 1088
页数:8
相关论文
共 31 条
[1]
MR arthrography of the glenohumeral joint: Two concentrations of gadoteridol versus Ringer solution as the intraarticular contrast material [J].
Binkert, CA ;
Zanetti, M ;
Gerber, C ;
Hodler, J .
RADIOLOGY, 2001, 220 (01) :219-224
[2]
INTRAARTICULAR DIFFUSION OF GD-DOTA AFTER INTRAVENOUS-INJECTION IN THE KNEE - MR-IMAGING EVALUATION [J].
DRAPE, JL ;
THELEN, P ;
GAYDEPASSIER, P ;
SILBERMANN, O ;
BENACERRAF, R .
RADIOLOGY, 1993, 188 (01) :227-234
[3]
Sample size estimation: How many individuals should be studied? [J].
Eng, J .
RADIOLOGY, 2003, 227 (02) :309-313
[4]
Engel A, 1990, Acta Orthop Scand Suppl, V240, P1
[5]
ENGEL A, 1990, ACTA ORTHOP SCA S240, V61, P1
[6]
Direct MR arthrography: A review of current use [J].
Grainger, AJ ;
Elliott, JM ;
Campbell, RSD ;
Tirman, PFJ ;
Steinbach, LS ;
Genant, HK .
CLINICAL RADIOLOGY, 2000, 55 (03) :163-175
[7]
SYNOVIAL-FLUIDS FACILITATE SMALL SOLUTE DIFFUSIVITY [J].
HADLER, NM .
ANNALS OF THE RHEUMATIC DISEASES, 1980, 39 (06) :580-585
[8]
POTENTIAL CONTRAST AGENTS FOR MR ARTHROGRAPHY - INVITRO EVALUATION AND PRACTICAL OBSERVATIONS [J].
HAJEK, PC ;
SARTORIS, DJ ;
NEUMANN, CH ;
RESNICK, D .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (01) :97-104
[9]
THE EFFECT OF INTRAARTICULAR GADOLINIUM-DTPA ON SYNOVIAL-MEMBRANE AND CARTILAGE [J].
HAJEK, PC ;
SARTORIS, DJ ;
GYLYSMORIN, V ;
HAGHIGHI, P ;
ENGEL, A ;
KRAMER, F ;
NEUMANN, CH ;
RESNICK, D .
INVESTIGATIVE RADIOLOGY, 1990, 25 (02) :179-183
[10]
EPINEPHRINE ENHANCED KNEE ARTHROGRAPHY [J].
HALL, FM .
RADIOLOGY, 1974, 111 (01) :215-217