The value of contrast enhanced ultrasonography in detection of liver metastases from colorectal cancer: A prospective double-blinded study

被引:64
作者
Larsen, Lars Peter Skovgaard
Rosenkilde, Mona
Christensen, Henrik
Bang, Niels
Bolvig, Lars
Christiansen, Thomas
Laurberg, Soren
机构
[1] Aarhus Univ Hosp, Dept Radiol, DK-8000 Aarhus C, Denmark
[2] Aarhus Univ Hosp, Dept Surg, Colorectal Sect, DK-8000 Aarhus C, Denmark
关键词
ultrasound contrast agent; liver neoplasms; metastases; colon cancer; rectum cancer;
D O I
10.1016/j.ejrad.2006.11.033
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Objective: To compare sensitivity and specificity of contrast enhanced ultrasonography (CEUS) with conventional ultrasonography (US) in detection of liver metastases in patients with colorectal adenocarcinoma (CRC) in a patient-by-patient analysis. Materials and methods: A prospective study of 461 consecutive patients referred to the Department of Colorectal Surgery, Aarhus University Hospital with primary or local recurrence of CRC. In order to detect possible liver metastases all patients underwent liver US, followed by CEUS by another investigator. Multislice CT scanning (MDCT), and intraoperative ultrasonography (IOUS) were then performed. Fine-needle biopsy was performed on all suspicious lesions. Each examination was interpreted blindly and the combination of biphasic MDCT, IOUs, follow up and biopsy was the gold standard. Results: Standard of reference found liver metastases in 54 patients (14.8%). Contrast enhanced ultrasonography improved the sensitivity significantly in detection of liver metastases from 0.69 by US to 0.80 (p = 0.03 1). In 24 patients, CEUS found a higher number of metastases than US (p < 0.00 1). The specificity (0.98) and the positive predictive value (0.86) was the same. Conclusion: Contrast enhanced ultrasonography improves sensitivity in detection of liver metastases in patients with CRC and in nearly half of the cases CEUS found a higher number of metastases than US. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:302 / 307
页数:6
相关论文
共 21 条
[1]
Improved detection of hepatic metastases with pulse-inversion US during the liver-specific phase of SHU 508A: Multicenter study [J].
Albrecht, T ;
Blomley, MJK ;
Burns, PN ;
Wilson, S ;
Harvey, CJ ;
Leen, E ;
Claudon, M ;
Calliada, F ;
Correas, JM ;
LaFortune, M ;
Campani, R ;
Hoffmann, CW ;
Cosgrove, DO ;
LeFevre, F .
RADIOLOGY, 2003, 227 (02) :361-370
[2]
Phase-inversion sonography during the liver-specific late phase of contrast enhancement: Improved detection of liver metastases [J].
Albrecht, T ;
Hoffmann, CW ;
Schmitz, SA ;
Schettler, S ;
Overberg, A ;
Germer, CT ;
Wolf, KJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) :1191-1198
[3]
Bruneton JN, 1996, EUR RADIOL, V6, P439
[4]
CLARKE MP, 1989, SURGERY, V106, P849
[5]
Detection of liver metastases with pulse inversion harmonic imaging: Preliminary results [J].
Dalla-Palma, L ;
Bertolotto, M ;
Quaia, E ;
Locatelli, M .
EUROPEAN RADIOLOGY, 1999, 9 (Suppl 3) :S382-S387
[6]
EDMONDSON HA, 1987, NEOPLASMS LIVER
[7]
Improved detection of liver metastases with contrast-enhanced wideband harmonic imaging: Comparison with CT findings [J].
Esteban, J.M. ;
Mollá, M.A. ;
Tomás, C. ;
Maldonado, L. .
European Journal of Ultrasound, 2002, 15 (03) :119-126
[8]
Accuracy of investigations for asymptomatic colorectal liver metastases [J].
Glover, C ;
Douse, P ;
Kane, P ;
Karani, J ;
Meire, H ;
Mohammadtaghi, S ;
Allen-Mersh, TG .
DISEASES OF THE COLON & RECTUM, 2002, 45 (04) :476-484
[9]
Hepatic malignancies: Improved detection with pulse-inversion US in late phase of enhancement with SHU 508A - Early experience [J].
Harvey, CJ ;
Blomley, MJK ;
Eckersley, RJ ;
Cosgrove, DO ;
Patel, N ;
Heckemann, RA ;
Butler-Barnes, J .
RADIOLOGY, 2000, 216 (03) :903-908
[10]
Hohmann J, 2003, ROFO-FORTSCHR RONTG, V175, P835