iTRAQ Underestimation in Simple and Complex Mixtures: "The Good, the Bad and the Ugly"

被引:393
作者
Ow, Saw Yen
Salim, Malinda
Noirel, Josselin
Evans, Caroline [2 ]
Rehman, Ishtiaq [2 ]
Wright, Phillip C. [1 ]
机构
[1] Univ Sheffield, Dept Chem & Proc Engn, ChELSI Inst, Sheffield S1 3JD, S Yorkshire, England
[2] Univ Sheffield, Sch Med, Mellanby Ctr Bone Res, Sheffield S10 2RX, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
iTRAQ underestimations; iTRAQ; quantitative proteomics; high-throughput proteomics; PULSED-Q DISSOCIATION; PROTEIN EXPRESSION; ABSOLUTE QUANTIFICATION; ISOBARIC TAGS; CANCER CELLS; QUANTITATION; IDENTIFICATION;
D O I
10.1021/pr900634c
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The increasing popularity of iTRAQ for quantitative proteomics applications makes it necessary to evaluate its relevance, accuracy, and precision for biological interpretation Here, we have assessed (a) the accuracy and precision of iTRAQ quantification in a controlled experimental setup, using low- and high-complexity protein mixtures; and (b) the potential pitfalls that hamper the applicability and attainable dynamic range of iTRAQ: isotopic contamination, background interference, and signal-to-noise ratio Our data suggest greater dynamic crosstalk between interfering factors affecting underestimations, and that these interferences were largely scenario-specific, dependent on sample complexity. The good is the potential for iTRAQ to provide accurate quantification spanning 2 orders of magnitude. This potential is however limited by two factors. (1) The bad: the existence of isotopic impurities that can be corrected for; provided accurate isotopic factors are at one's disposal. (2) The ugly. we demonstrate here the interference of mixed MS/MS contribution occurring during precursor selection, an issue that is currently very difficult to minimize. In light of our results, we propose a list of advice for iTRAQ data analysis that could routinely ameliorate quantitative interpretation of proteomic data sets
引用
收藏
页码:5347 / 5355
页数:9
相关论文
共 21 条
[1]   Differential Protein Expression Analysis Using Stable Isotope Labeling and PQD Linear Ion Trap MS Technology [J].
Armenta, Jenny M. ;
Hoeschele, Ina ;
Lazar, Iulia M. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (07) :1287-1302
[2]   Robust and sensitive iTRAQ quantification on an LTQ orbitrap mass spectrometer [J].
Bantscheff, Marcus ;
Boesche, Markus ;
Eberhard, Dirk ;
Matthieson, Toby ;
Sweetman, Gavain ;
Kuster, Bernhard .
MOLECULAR & CELLULAR PROTEOMICS, 2008, 7 (09) :1702-1713
[3]   Quantitative mass spectrometry in proteomics: a critical review [J].
Bantscheff, Marcus ;
Schirle, Markus ;
Sweetman, Gavain ;
Rick, Jens ;
Kuster, Bernhard .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (04) :1017-1031
[4]   Reporting protein identification data - The next generation of guidelines [J].
Bradshaw, RA ;
Burlingame, AL ;
Carr, S ;
Aebersold, R .
MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (05) :787-788
[5]   8-Plex quantitation of changes in cerebrospinal fluid protein expression in subjects undergoing intravenous immunoglobulin treatment for Alzheimer's disease [J].
Choe, Leila ;
D'Ascenzo, Mark ;
Relkin, Norman R. ;
Pappin, Darryl ;
Ross, Philip ;
Williamson, Brian ;
Guertin, Steven ;
Pribil, Patrick ;
Lee, Kelvin H. .
PROTEOMICS, 2007, 7 (20) :3651-3660
[6]   Isobaric tags for relative and absolute quantitation (iTRAQ) reproducibility: Implication of multiple injections [J].
Chong, PK ;
Gan, CS ;
Pham, TK ;
Wright, PC .
JOURNAL OF PROTEOME RESEARCH, 2006, 5 (05) :1232-1240
[7]  
D'Ascenzo Mark, 2008, Briefings in Functional Genomics & Proteomics, V7, P127, DOI 10.1093/bfgp/eln007
[8]   Multiple reaction monitoring of mTRAQ-labeled peptides enables absolute quantification of endogenous levels of a potential cancer marker in cancerous and normal endometrial tissues [J].
DeSouza, Leroi V. ;
Taylor, Adrian M. ;
Li, Wei ;
Minkoff, Marjorie S. ;
Romaschin, Alexander D. ;
Colgan, Terence J. ;
Siu, K. W. Michael .
JOURNAL OF PROTEOME RESEARCH, 2008, 7 (08) :3525-3534
[9]   Absolute Quantification of Potential Cancer Markers in Clinical Tissue Homogenates Using Multiple Reaction Monitoring on a Hybrid Triple Quadrupole/Linear Ion Trap Tandem Mass Spectrometer [J].
DeSouza, Leroi V. ;
Romaschin, Alexander D. ;
Colgan, Terence J. ;
Siu, K. W. Michael .
ANALYTICAL CHEMISTRY, 2009, 81 (09) :3462-3470
[10]   Technical, experimental, and biological variations in isobaric tags for relative and absolute quantitation (iTRAQ) [J].
Gan, Chee Sian ;
Chong, Poh Kuan ;
Pham, Trong Khoa ;
Wright, Phillip C. .
JOURNAL OF PROTEOME RESEARCH, 2007, 6 (02) :821-827