Simultaneous determination of BNP7787 and its metabolite mesna in plasma and tissue by micro-HPLC with a dual electrochemical detector

被引:15
作者
Verschraagen, M
Zwiers, THU
Torun, E
Donker, MG
Reinhoud, NJ
Van Der Vijgh, WJF
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Med Oncol, KRIGO, NL-1007 MB Amsterdam, Netherlands
[2] Antec Leyden BV, NL-2382 NV Zoeterwoude, Netherlands
关键词
BNP7787; mesna; micro-HPLC; dual electrochemical detector; plasma; tissue;
D O I
10.1002/jps.10363
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Sensitive, accurate, and precise assays are described to determine BNP7787 (disodium 2,2'-dithio-bis-ethane sulfonate) and its metabolite mesna (sodium 2-mercaptoethane sulfonate) simultaneously in plasma and tissue by micro-high-performance liquid chromatography (HPLC) with dual electrochemical detection. After separation of BNP7787 and mesna by micro-HPLC, the disulfide BNP7787 was reduced to mesna by a reactor cell with a glassy carbon working electrode (-1.6 V versus Hy-REF). At the second electrode, which consisted of a gold wall-jet electrode, the mesna generated from BNP7787 and the mesna already present in the samples were detected (+0.85 V versus Ag/AgCl). The lower limit of quantification (LLQ) of both compounds was 3 muM in plasma and 20 nmol/g in tissue. The dynamic range of the assay in plasma was 3-120 muM for mesna and 15-1200 muM for BNP7787. In tissue, the dynamic range was 20-2000 nmol/g for both compounds. The recovery of mesna from plasma and tissue ranged from 61.4 to 90.5% and 82.7 to 90.2%, respectively, and seemed to be concentration dependent. The recovery of BNP7787 from plasma and tissue was complete (i.e., 101.5 and 96.4%, respectively). The within- and between-day accuracy and precision for the plasma and tissue assay were within 14 and 7%, respectively. The utility of the assay was shown by determination of the stability of mesna and BNP7787 in a kidney sample of a rat and by analysis of plasma samples obtained from a patient receiving 18.4 g/m(2) BNP7787 as a 15-min intravenous infusion. (C) 2003 Wiley-Liss, Inc. and the American Pharmaceutical Association.
引用
收藏
页码:1040 / 1050
页数:11
相关论文
共 22 条
[1]   DUAL ELECTRODE LIQUID-CHROMATOGRAPHY DETECTOR FOR THIOLS AND DISULFIDES [J].
ALLISON, LA ;
SHOUP, RE .
ANALYTICAL CHEMISTRY, 1983, 55 (01) :8-12
[2]   A strategy for validation of bioanalytical methods [J].
Braggio, S ;
Barnaby, RJ ;
Grossi, P ;
Cugola, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (04) :375-388
[3]   LIQUID-CHROMATOGRAPHIC ANALYSIS OF MESNA AND DIMESNA IN PLASMA AND URINE OF PATIENTS TREATED WITH MESNA [J].
ELYAZIGI, A ;
YUSUF, A ;
ALRAWITHI, S .
THERAPEUTIC DRUG MONITORING, 1995, 17 (02) :153-158
[4]   Pharmacokinetics of mesna and dimesna after simultaneous intravenous bolus and infusion administration in patients undergoing bone marrow transplantation [J].
ElYazigi, A ;
Ernst, P ;
AlRawithi, S ;
Legayada, E ;
Raines, DA .
JOURNAL OF CLINICAL PHARMACOLOGY, 1997, 37 (07) :618-624
[5]  
Glowacki R, 2001, J CHROMATOGR A, V914, P29
[6]  
Goren MP, 1998, CLIN CANCER RES, V4, P2313
[7]  
Goren MP, 1998, CANCER RES, V58, P4358
[8]   THE SIMULTANEOUS DETERMINATION OF OXIDIZED AND REDUCED GLUTATHIONES IN LIVER-TISSUE BY ION-PAIRING REVERSE PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A COULOMETRIC ELECTROCHEMICAL DETECTOR [J].
HARVEY, PRC ;
ILSON, RG ;
STRASBERG, SM .
CLINICA CHIMICA ACTA, 1989, 180 (03) :203-212
[9]  
Hausheer FH, 1998, SEMIN ONCOL, V25, P584
[10]   PHARMACOKINETICS OF INTRAVENOUS AND ORAL SODIUM 2-MERCAPTOETHANE SULFONATE (MESNA) IN NORMAL SUBJECTS [J].
JAMES, CA ;
MANT, TGK ;
ROGERS, HJ .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1987, 23 (05) :561-568