Rapid rate transcranial magnetic stimulation - a safety study

被引:46
作者
Jahanshahi, M
Ridding, MC
Limousin, P
Profice, P
Fogel, W
Dressler, D
Fuller, R
Brown, RG
Brown, P
Rothwell, JC
机构
[1] UCL Natl Hosp Neurol & Neurosurg, Inst Neurol, Dept Clin Neurol, London WC1N 3BG, England
[2] UCL Natl Hosp Neurol & Neurosurg, MRC, Human Movement & Balance Unit, London WC1N 3BG, England
[3] Univ Cattolica Sacro Cuore, Inst Neurol, I-00168 Rome, Italy
[4] Univ Heidelberg, Dept Neurol, Heidelberg, Germany
来源
ELECTROMYOGRAPHY AND MOTOR CONTROL-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY | 1997年 / 105卷 / 06期
基金
英国惠康基金;
关键词
rapid rate magnetic stimulation; safety study;
D O I
10.1016/S0924-980X(97)00057-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We assessed the safety of repeated short trains (4 stimuli) of rapid-rate transcranial magnetic stimulation (rrTMS) over the left motor cortex in 6 healthy normal subjects. rrTMS involved two separate blocks of 50 consecutive trains of 4 stimuli at a frequency of 20 Hz and an intensity of 5-10% above active motor threshold. We monitored EEG, and assessed aspects of neurological (balance, gait, two-point discrimination, blood pressure, pulse rate), cognitive (attention, memory executive function) and motor function (speed of movement initiation and execution and manual dexterity) before and after the two blocks of rrTMS. EMG was also recorded from a number of hand, forearm and arm muscles contralateral to the site of stimulation. Two blocks of repeated rrTMS at 20 Hz and 5-10% above active motor threshold did not produce any adverse effects. Measures of neurological, cognitive and motor function showed no change following rrTMS. From the EMG recording there was evidence of increase in the amplitude of the motor evoked potentials (MEPs) recorded from the biceps in one subject during the first block of rrTMS, but this did not occur in the second block. A similar magnification of MEPs was also observed in another subject only during the second block of stimulation. When applied using parameters falling within published guidelines (Pascual-Leone el al., 1993; Pascual-Leone et al., 1994), repeated rrTMS is a relatively safe technique in healthy normal subjects. As rrTMS allows disruption of cortical function for a longer period, it has the potential of becoming a particularly useful tool for the study of cognitive function as well as sensory or motor function. (C) 1997 Elsevier Science ireland Ltd.
引用
收藏
页码:422 / 429
页数:8
相关论文
共 24 条
  • [1] MEASUREMENT OF INFORMATION-PROCESSING DELAYS IN HUMAN VISUAL-CORTEX WITH REPETITIVE MAGNETIC COIL STIMULATION
    AMASSIAN, VE
    MACCABEE, PJ
    CRACCO, RQ
    CRACCO, JB
    RUDELL, AP
    EBERLE, L
    [J]. BRAIN RESEARCH, 1993, 605 (02) : 317 - 321
  • [2] AMASSIAN VE, 1990, J PHYSL, V430, P109
  • [3] BARKER AT, 1985, LANCET, V1, P1106
  • [4] TRANSCRANIAL MAGNETIC STIMULATION - AN ASSESSMENT OF COGNITIVE AND OTHER CEREBRAL EFFECTS
    BRIDGERS, SL
    DELANEY, RC
    [J]. NEUROLOGY, 1989, 39 (03) : 417 - 419
  • [5] BROWN P, 1996, LANCET, V348, P459
  • [6] EPILEPTIC SEIZURES TRIGGERED DIRECTLY BY FOCAL TRANSCRANIAL MAGNETIC STIMULATION
    CLASSEN, J
    WITTE, OW
    SCHLAUG, G
    SEITZ, RJ
    HOLTHAUSEN, H
    BENECKE, R
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1995, 94 (01): : 19 - 25
  • [7] SAFETY ASPECTS OF TRANSCRANIAL BRAIN-STIMULATION IN MAN TESTED BY SINGLE PHOTON EMISSION-COMPUTED TOMOGRAPHY
    DRESSLER, D
    VOTH, E
    FELDMANN, M
    BENECKE, R
    [J]. NEUROSCIENCE LETTERS, 1990, 119 (02) : 153 - 155
  • [8] DAILY REPETITIVE TRANSCRANIAL MAGNETIC STIMULATION (RTMS) IMPROVES MOOD IN DEPRESSION
    GEORGE, MS
    WASSERMANN, EM
    WILLIAMS, WA
    CALLAHAN, A
    KETTER, TA
    BASSER, P
    HALLETT, M
    POST, RM
    [J]. NEUROREPORT, 1995, 6 (14) : 1853 - 1856
  • [9] INDUCTION OF A RECALL DEFICIT BY RAPID-RATE TRANSCRANIAL MAGNETIC STIMULATION
    GRAFMAN, J
    PASCUALLEONE, A
    ALWAY, D
    NICHELLI, P
    GOMEZTORTOSA, E
    HALLETT, M
    [J]. NEUROREPORT, 1994, 5 (09) : 1157 - 1160
  • [10] HOMBERG V, 1989, LANCET, V2, P1223