Improved assessment of mitral valve stenosis by volumetric real-time three-dimensional echocardiography

被引:89
作者
Binder, TM
Rosenhek, R
Porenta, G
Maurer, G
Baumgartner, H
机构
[1] Univ Vienna, Dept Cardiol, A-1090 Vienna, Austria
[2] Ludwig Boltzmann Inst, Vienna, Austria
关键词
D O I
10.1016/S0735-1097(00)00852-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study was performed to determine the feasibility, accuracy and reproducibility of real-time volumetric three-dimensional echocardiography (3-D echo) for the estimation of mitral valve area in patients with mitral valve stenosis. BACKGROUND Planimetry of the mitral valve area (MVA) by two-dimensional echocardiography (2-D echo) requires a favorable parasternal acoustic window and depends on operator skill. Transthoracic volumetric 3-D echo allows reconstruction of multiple 2-D planes in any desired orientation and is not limited to parasternal acquisition, and could thus enhance the accuracy and feasibility of calculating MVA. METHODS In 48 patients with mitral stenosis (40 women; mean age 61 +/- 13 years) MVA was determined by planimetry using volumetric 3-D echo and compared with measurements obtained by 2-D echo and Doppler pressure half-time (PHT). All measurements were performed by two independent observers. Volumetric data were acquired from an apical view. RESULTS Although 2-D echo allowed planimetry of the mitral valve in 43 of 48 patients (89%), calculation of the MVA was possible in all patients when 3-D echo was used. Mitral valve area by 3-D echo correlated well, with MVA by 2-D echo (r = 0.93, mean difference, 0.09 +/- 0.14 cm(2)) and by PHT (r = 0.87, mean difference, 0.16 +/- 0.19 cm(2)). Interobserver variability was significantly less for 3-D echo than for 2-D echo (SD 0.08 cm(2) versus SD 0.23 cm(2), p < 0.001). Furthermore, it was much easier and faster to define the image plane with the smallest orifice area when 3-D echo was used. CONCLUSIONS Transthoracic real-time volumetric 3-D echo provides accurate and highly reproducible measurements of mitral valve area and can easily be performed from an apical approach. (J Am Coll Cardiol 2000;36:1355-61) (C) 2000 by the American College of Cardiology.
引用
收藏
页码:1355 / 1361
页数:7
相关论文
共 29 条
  • [11] AORTIC REGURGITATION SHORTENS DOPPLER PRESSURE HALF-TIME IN MITRAL-STENOSIS - CLINICAL-EVIDENCE, INVITRO SIMULATION AND THEORETIC ANALYSIS
    FLACHSKAMPF, FA
    WEYMAN, AE
    GILLAM, L
    CHUNMING, L
    ABASCAL, VM
    THOMAS, JD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (02) : 396 - 404
  • [12] COMPARISON OF HEMODYNAMIC PRESSURE HALF-TIME METHOD AND GORLIN FORMULA WITH DOPPLER AND ECHOCARDIOGRAPHIC DETERMINATIONS OF MITRAL-VALVE AREA IN PATIENTS WITH COMBINED MITRAL-STENOSIS AND REGURGITATION
    FREDMAN, CS
    PEARSON, AC
    LABOVITZ, AJ
    KERN, MJ
    [J]. AMERICAN HEART JOURNAL, 1990, 119 (01) : 121 - 129
  • [13] HYDRAULIC FORMULA FOR CALCULATION OF THE AREA OF THE STENOTIC MITRAL VALVE, OTHER CARDIAC VALVES, AND CENTRAL CIRCULATORY SHUNTS .1.
    GORLIN, R
    GORLIN, SG
    [J]. AMERICAN HEART JOURNAL, 1951, 41 (01) : 1 - 29
  • [14] HAMMERMEISTER KE, 1973, BRIT HEART J, V35, P392
  • [15] NON-INVASIVE ASSESSMENT OF ATRIOVENTRICULAR PRESSURE HALF-TIME BY DOPPLER ULTRASOUND
    HATLE, L
    ANGELSEN, B
    TROMSDAL, A
    [J]. CIRCULATION, 1979, 60 (05) : 1096 - 1104
  • [16] REASSESSMENT OF VALVE AREA DETERMINATIONS IN MITRAL-STENOSIS BY THE PRESSURE HALF-TIME METHOD - IMPACT OF LEFT-VENTRICULAR STIFFNESS AND PEAK DIASTOLIC PRESSURE DIFFERENCE
    KARP, K
    TEIEN, D
    BJERLE, P
    ERIKSSON, P
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (03) : 594 - 599
  • [17] KAWAHARA T, 1991, J AM COLL CARDIOL, V18, P85
  • [18] Klarich K W, 1996, J Am Soc Echocardiogr, V9, P684, DOI 10.1016/S0894-7317(96)90065-6
  • [19] Quantification of mitral valve stenosis by three-dimensional transesophageal echocardiography
    Kupferwasser, I
    MohrKahaly, S
    Menzel, T
    Spiecker, M
    Dohmen, G
    Mayer, E
    Oelert, H
    Erbel, R
    Meyer, J
    [J]. INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1996, 12 (04): : 241 - 247
  • [20] RELIABILITY AND REPRODUCIBILITY OF 2 DIMENSIONAL ECHOCARDIOGRAPHIC MEASUREMENT OF THE STENOTIC MITRAL-VALVE ORIFICE AREA
    MARTIN, RP
    RAKOWSKI, H
    KLEIMAN, JH
    BEAVER, W
    LONDON, E
    POPP, RL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1979, 43 (03) : 560 - 568