Effects of hip joint centre mislocation on gait analysis results

被引:169
作者
Stagni, R
Leardini, A
Cappozzo, A
Benedetti, MG
Cappello, A
机构
[1] Univ Bologna, Dipartimento Elettron Informat & Sistemist, I-40136 Bologna, Italy
[2] Ist Ortoped Rizzoli, Movement Anal Lab, Bologna, Italy
[3] Univ Sassari, Dipartimento Sci Biomed, I-07100 Sassari, Italy
关键词
gait analysis; hip joint centre; error propagation; resultant moments; joint angles;
D O I
10.1016/S0021-9290(00)00093-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Methods to determine the hip joint centre (HJC) location are necessary in gait analysis. It has been demonstrated that the methods proposed in the literature involve large mislocation errors. The choice should be made according to the extent by which HJC location errors distort the estimates of angles and resultant moments at the hip and knee joints. This study aimed at quantifying how mislocation errors propagate to these gait analysis results. Angles and moments at the hip and knee joint were calculated for five able-bodied subjects during level walking. The nominal position of the HJC was determined as the position of the pivot point of a 3D movement of the thigh relative to the pelvis. Angles and moments were then re-calculated after having added to HJC co-ordinates errors in the range of +/- 30 mm. Angles and moments at both hip and knee joints were affected by HJC mislocation. The hip moments showed the largest propagation error: a 30 mm HJC anterior mislocation resulted in a propagated error into flexion/extension component of about -22%. The hip abduction/adduction moment was found the second largest affected quantity: a 30 mm lateral HJC mislocation produced a propagated error of about -15%. Finally, a 30 mm posterior HJC mislocation produced a delay of the flexion-to-extension timing in the order of 25% of the stride duration. HJC estimation methods with minimum antero-posterior error should therefore be preferred. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1479 / 1487
页数:9
相关论文
共 24 条
[1]   A STUDY OF LOWER-LIMB MECHANICS DURING STAIR-CLIMBING [J].
ANDRIACCHI, TP ;
ANDERSSON, GBJ ;
FERMIER, RW ;
STERN, D ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (05) :749-757
[2]  
ANDRIACCHI TP, 1983, P NATO ADV STUDY I B, P83
[3]   PREDICTION OF HIP-JOINT CENTER LOCATION FROM EXTERNAL LANDMARKS [J].
BELL, AL ;
BRAND, RA ;
PEDERSEN, DR .
HUMAN MOVEMENT SCIENCE, 1989, 8 (01) :3-16
[4]   A COMPARISON OF THE ACCURACY OF SEVERAL HIP CENTER LOCATION PREDICTION METHODS [J].
BELL, AL ;
PEDERSEN, DR ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1990, 23 (06) :617-621
[5]   Optimization and smoothing techniques in movement analysis [J].
Cappello, A ;
LaPalombara, PF ;
Leardini, B .
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1996, 41 (03) :137-151
[6]   GAIT ANALYSIS METHODOLOGY [J].
CAPPOZZO, A .
HUMAN MOVEMENT SCIENCE, 1984, 3 (1-2) :27-50
[7]   POSITION AND ORIENTATION IN-SPACE OF BONES DURING MOVEMENT - ANATOMICAL FRAME DEFINITION AND DETERMINATION [J].
CAPPOZZO, A ;
CATANI, F ;
DELLA CROCE, U ;
LEARDINI, A .
CLINICAL BIOMECHANICS, 1995, 10 (04) :171-178
[8]   Position and orientation in space of bones during movement: Experimental artefacts [J].
Cappozzo, A ;
Catani, F ;
Leardini, A ;
Benedetti, MG ;
DellaCroce, U .
CLINICAL BIOMECHANICS, 1996, 11 (02) :90-100
[9]  
CAPPOZZO A, 1986, BIOL BIOMECHANICAL P, P429
[10]   BIOMECHANICAL INVESTIGATION OF HUMAN HIP [J].
CROWNINSHIELD, RD ;
JOHNSTON, RC ;
ANDREWS, JG ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1978, 11 (1-2) :75-85