Optimized suppression of adducts in polymerase chain reaction products for semi-quantitative SNP genotyping by liquid chromatography-mass spectrometry

被引:21
作者
Oberacher, H
Parson, W
Hölzl, G
Oefner, PJ
Huber, CG
机构
[1] Univ Saarland, Dept Chem, D-66041 Saarbrucken, Germany
[2] Stanford Genome Technol Ctr, Palo Alto, CA USA
[3] Innsbruck Med Univ, Inst Legal Med, Innsbruck, Austria
关键词
D O I
10.1016/j.jasms.2004.09.004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
While electrospray ionization mass spectrometry has shown great potential for the identification of genotypes in DNA sequences amplified by polymerase chain reaction (PCR), the quantitative determination of allele frequencies remains challenging because of the presence of cationic adducts in the mass spectra which severely impairs accuracy of quantitation. We report here on the elaboration of an optimized desalting protocol for ion-pair reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry (ICEMS) of PCR amplicons which facilitates the genotyping of single nucleotide polymorphisms (SNPs). Chromatographic purification at temperatures between 50 and 70 degreesC using monolithic reversed-phase columns and acetonitrile gradients in aqueous, 20-30 mmol/l butyldimethyl-ammonium bicarbonate enabled the mass spectrometric analysis of nucleic acid solutions containing up to 1.7 mol/l sodium chloride. A further improvement in removal of metal cations was achieved upon the addition of 5-10 mmol/l ethylenediaminetetraacetic acid (EDTA) to the sample solution prior to liquid chromatography. ICEMS was used for the semi-quantitative genotyping of SNPs amplified from the tetraploid genome of potato cultivars. Using a quadrupole ion trap mass spectrometer, allele frequencies were determined with an accuracy of 2-9% by measuring the relative intensities of the signals corresponding to the molecular mass of each of the alleles in the deconvoluted mass spectra. ICEMS results correlated well with those obtained by pyrosequencing, single nucleotide primer extension, and conventional dideoxy sequencing. (C) 2004 American Society for Mass Spectrometry.
引用
收藏
页码:1897 / 1906
页数:10
相关论文
共 48 条
[21]   High-throughput methods for detection of genetic variation [J].
Kristensen, VN ;
Kelefiotis, D ;
Kristensen, T ;
Borresen-Dale, AL .
BIOTECHNIQUES, 2001, 30 (02) :318-+
[22]  
Li J, 1999, ELECTROPHORESIS, V20, P1258, DOI 10.1002/(SICI)1522-2683(19990101)20:6<1258::AID-ELPS1258>3.0.CO
[23]  
2-V
[24]   MOLECULAR-MASS MEASUREMENT OF INTACT RIBONUCLEIC-ACIDS VIA ELECTROSPRAY-IONIZATION QUADRUPOLE MASS-SPECTROMETRY [J].
LIMBACH, PA ;
CRAIN, PF ;
MCCLOSKEY, JA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (01) :27-39
[25]  
Liu CL, 1997, J MASS SPECTROM, V32, P425, DOI 10.1002/(SICI)1096-9888(199704)32:4<425::AID-JMS493>3.0.CO
[26]  
2-E
[27]  
Muddiman DC, 1999, RAPID COMMUN MASS SP, V13, P1201, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1201::AID-RCM643>3.0.CO
[28]  
2-X
[29]  
Muddiman DC, 1996, J AM SOC MASS SPECTR, V7, P697, DOI 10.1016/1044-0305(96)80516-2
[30]   Evaluation of sample preparation techniques for mass measurements of PCR products using ESI-FT-ICR mass spectrometry [J].
Null, AP ;
George, LT ;
Muddiman, DC .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (04) :338-344