Abdominal aortic aneurysm size regression after endovascular repair is endograft dependent

被引:85
作者
Bertges, DJ
Chow, K
Wyers, MC
Landsittel, D
Frydrych, AV
Stavropoulos, W
Tan, WA
Rhee, RY
Fillinger, MF
Fairman, RM
Makaroun, MS
机构
[1] Univ Pittsburgh, Med Ctr, Pittsburgh, PA 15260 USA
[2] Univ Penn, Hlth Syst, Philadelphia, PA 19104 USA
[3] Dartmouth Hitchcock Med Ctr, Lebanon, NH 03766 USA
[4] Pittsburgh Canc Inst, Dept Biostat, Pittsburgh, PA USA
[5] Univ Pittsburgh, Med Ctr, Shadyside Hosp, Pittsburgh Vasc Inst, Pittsburgh, PA 15260 USA
关键词
D O I
10.1067/mva.2003.212
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study was performed to determine whether abdominal aortic aneurysm (AAA) regression is different with various endografts after endovascular repair. Methods. A four-center retrospective review of size change after endovascular AAA repair was performed. Consecutive patients with at least 1-year follow-up and available imaging studies were included. Three hundred ninety patients received either the Ancure, AneuRx, Excluder, or Talent endograft. AAA size and endoleak status were recorded from computed tomography (CT) scans at the initial postoperative follow-up visit and at I and 2 years thereafter. AAA size was defined as the minor axis of the infrarenal aorta on the largest axial section on the two-dimensional CT scan. A change in AAA size of 0.5 cm or greater from baseline was considered clinically significant. The effect of initial size, endoleak, and type of endograft on AAA regression was analyzed. Results: Mean baseline size was significantly greater with Talent endografts and smaller with Excluder endografts. Clinically significant regression in AAA size occurred in nearly three fourths of patients with Ancure and Talent endografts at 2 years. Regression in AAA size was less frequent with the AneuRx (46%) and Excluder (44%) devices. Initial size, endoleak, and endograft type were significant predictors of regression at multivariate analysis at I year. However, by 2 years only endograft type was still an independent predictor of AAA shrinkage. Conclusions. Long-term morphologic changes after endovascular aneurysm repair depend on endograft type.
引用
收藏
页码:716 / 723
页数:8
相关论文
共 34 条
[1]  
AGRESTI A, 1990, CATEGORICAL DATA ANA, P111
[2]   Reporting standards for infrarenal endovascular abdominal aortic aneurysm repair [J].
Ahn, SS ;
Rutherford, RB ;
Johnston, KW ;
May, J ;
Veith, FJ ;
Baker, JD ;
Ernst, CB ;
Moore, WS .
JOURNAL OF VASCULAR SURGERY, 1997, 25 (02) :405-410
[3]   Mid-term results of a second generation bifurcated endovascular graft for abdominal aortic aneurysm repair: The French Vanguard trial [J].
Becquemin, JP ;
Lapie, V ;
Favre, JP ;
Rousseau, H .
JOURNAL OF VASCULAR SURGERY, 1999, 30 (02) :209-218
[4]   Device migration after endoluminal abdominal aortic aneurysm repair: Analysis of 113 cases with a minimum follow-up period of 2 years [J].
Cao, P ;
Verzini, F ;
Zannetti, S ;
De Rango, P ;
Parlani, G ;
Lupattelli, L ;
Maselli, A .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (02) :229-235
[5]   Failure of endovascular abdominal aortic aneurysm graft limbs [J].
Carpenter, JP ;
Neschis, DG ;
Fairman, RM ;
Barker, CF ;
Golden, MA ;
Velazquez, OC ;
Mitchell, ME ;
Baum, RA .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (02) :296-302
[6]   Reporting standards for endovascular aortic aneurysm repair [J].
Chaikof, EL ;
Blankensteijn, JD ;
Harris, PL ;
White, GH ;
Zarins, CK ;
Bernhard, VM ;
Matsumura, JS ;
May, J ;
Veith, FJ ;
Fillinger, MF ;
Rutherford, RB ;
Kent, KC .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (05) :1048-1060
[7]  
Criado FJ, 2001, J VASC SURG, V33, pS146
[8]   Endoleak: Predictive value for aneurysm growth at 3 years [J].
Deaton, DH ;
Makaroun, MS ;
Fairman, RM .
ANNALS OF VASCULAR SURGERY, 2002, 16 (01) :37-42
[9]   A multicenter experience with the Talent endovascular graft for the treatment of abdominal aortic aneurysms [J].
Faries, PL ;
Brener, BJ ;
Connelly, TL ;
Katzen, BT ;
Briggs, VL ;
Burks, JA ;
Gravereaux, EC ;
Carroccio, A ;
Morrissey, NJ ;
Teodorescu, V ;
Won, J ;
Sparacino, S ;
Chae, KS ;
Hollier, LH ;
Marin, ML .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (06) :1123-1128
[10]   VARIABILITY IN MEASUREMENT OF ABDOMINAL AORTIC-ANEURYSMS [J].
LEDERLE, FA ;
WILSON, SE ;
JOHNSON, GR ;
REINKE, DB ;
LITTOOY, FN ;
ACHER, CW ;
MESSINA, LM ;
BALLARD, DJ ;
ANSEL, HJ .
JOURNAL OF VASCULAR SURGERY, 1995, 21 (06) :945-952